The full menu structure for the panel can only be accessed while in Engineer program mode. The structure is
shown in the following table:
Enter Engineer program mode. Press [PROG] [9] [9] [9] [9].
0 = Walk Test
The walk test function allows each detector to be checked in order to verify that they are functioning correctly.
A tone is generated as each zone is activated (opened).
LCD keypad
•
Press [up arrow] for menu Walk Test.
•
Press [SET] or [0]. Zones 1-8 have a zero (0)
below each number.
•
When a zone is sucsessfully tested, number 1
replaces the 0. Zones are added to list as each
one is activated.
•
Press [RESET] to leave the menu or [SET] to
restart the Walk Test.
LED keypad
•
Press [0] for menu Walk Test.
•
Press [SET]. Zones 1-8 are off
•
When a zone is sucsessfully tested, the LED is on.
Zones are added to list as each one is activated.
•
The Tamper LED comes on when tested.
•
Press [RESET] to leave the menu or [SET] to restart
the Walk Test.
MENU OPTIONS
0 = Walk Test
1 = Alarm Test
2 = Test Outputs
3 = System Flags
4 = Time and Date
6 = Zone Names
Table 2. Menu Options
Accenta/Optima Engineer's Manual
7 = Timers
8 = Codes
C = View Event Log
O = Omit Allow & Double Knock
P = Set up Programs
0>Walk Test
0>Walk Test
0>Walk Test
0>Walk Test
0>Walk Test
0>Walk Test
0>Walk Test
0>Walk Test
0>Walk Test
0>Walk Test
18
[up arrow]
[SET] or [0]
12345678
12345678
12345678
12345678
12345678
TP
TP
TP
TP
TP
00000000
00000000
00000000
00
00
00
00000000
00000000
00
00
[RESET]
[SET]
1
2
3
4
5
6
[RESET]
1
2
3
4
5
6
7
8
7
8