Relay Port Setup - NEC SL1100 Programming Manual

Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

SL1100
Level:
IN
Description
Use Program 10-61 : Relay Port Setup to defines the relay port type on the 084M.
Program
10
Input Data
Item
No.
01
Relay Type
02
Destination Selection
Conditions
None
Feature Cross Reference
None
2-54
Program 10 : System Configuration Setup
Relay Port No.
Item

10-61 : Relay Port Setup

Input Data
0 = No Setting
1 = External MOH
2 = BGM resource
3 = External Speaker
4 = Door Phone
10-61-01 = 1 or 2 : Not Use
10-61-01 = 3 : 1 ~ 3 External Speaker Message
No.
10-61-01 = 4 : 1 ~ 6 Door Phone No.
Program 10 : System Configuration Setup
ISSUE 6.0
1 ~ 6
Default
0
0 (Not Used)

Hide quick links: