Program 15 : Extension, Basic Setup

15-24 : Registration of Standard SIP Terminal

Level:
IN
(This Program is available for V1.5 or higher)
Description
Use Program 15-24 : Registration of Standard SIP Terminal to register data in the standard SIP
terminal where Register is not used.
Input Data
Item
Item
No.
01
Using IP Address
02
Call Procedure Port
03
Registration Setting
when REGISTER isn't
used
Conditions
None
Feature Cross Reference
None
Programming Manual
Input Data
0.0.0.0 ~
IP Address of the standard SIP terminal
255.255.255.255
that is used as the SIP extension. When
Program 15-24-03 is set to 1, this Program
cannot be changed from 0.0.0.0 (except
using PCProgramming).
0 ~ 65535
Call procedure port of the standard SIP
terminal that is used as SIP extension.
0 = Disable
Enables or disables the Registration meth-
1 = Enable
od. An error will occur if Program 15-24-01
is 0.0.0.0 and this Program is set to 1 (ex-
cept using PCProgramming).
Description
SL1100
Program
15
Default
0.0.0.0
5060
0