NEC SL1100 Programming Manual page 476

Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

SL1100
Item
No.
04
Max. Detect Level
Program
80
05
Forward Twist Level
06
Backward Twist Level 0 ~ 9 (1 dB ~ 10 dB)
07
ON Detect Time
08
OFF Detect Time
09
Area Type
Default
Item
No
01
Detect Level
02
Start delay time
03
Min. detect level
04
Max. detect level
05
Forward twist level
06
Backward twist level
07
ON detect time
08
OFF detect time
09
Area Type
Conditions
None
Feature Cross Reference
None
2-456
Item
Input Data
0 ~ 15
DTMF Tone 0 = 0 dBm
(0) to - 15 dBm (15)
DTMF Tone 1 = - 5 dBm
(0) to - 20 dBm (15)
DTMF Tone 2 = - 10
dBm (0) to - 25 dBm (15)
DTMF Tone 3 = - 15
dBm (0) to - 30 dBm (15)
DTMF Tone 4 = - 20
dBm (0) to - 35 dBm (15)
DTMF Tone 5 = - 25
dBm (0) to - 40 dBm (15)
DTMF Tone 6 = - 30
dBm (0) to - 45 dBm (15)
0 ~ 9 (1 dB ~ 10 dB)
1 ~ 255 (15 + 15 ms ~
3825 ms)
1 ~ 255 (15 + 15 ms ~
3825 ms)
0 = Other
1 = Aust
Item
Type 1
0
0
10 (- 20 dBm)
2 (- 2 dBm)
5 (6 dBm)
0 (1 dBm)
1 (30 ms)
1 (30 ms)
0
Description
Type 2
Type 3
0
0
0
0
15 (- 25 dBm)
15 (- 25 dBm)
2 (- 2 dBm)
2 (- 2 dBm)
5 (6 dBm)
5 (6 dBm)
0 (1 dBm)
0 (1 dBm)
1 (30 ms)
1 (30 ms)
1 (30 ms)
1 (30 ms)
0
0
Program 80 : Basic Hardware Setup for System
ISSUE 6.0
Default
Refer below
Refer below
Refer below
Refer below
Refer below
Refer below
Type 4
Type 5
0
0
0
0
10 (- 20 dBm)
10 (- 20 dBm)
2 (- 2 dBm)
2 (- 2 dBm)
5 (6 dBm)
5 (6 dBm)
0 (1 dBm)
0 (1 dBm)
1 (30 ms)
1 (30 ms)
1 (30 ms)
1 (30 ms)
0
0

Hide quick links: