Error Messages - Fujitsu primergy TX150 User Manual

Table of Contents

Advertisement

Chapter 9 Operation and Maintenance
■ CD-ROM Drive Unit / DVD-RAM Drive Unit
Cannot read data.
• Check to see whether the CD-ROM is inserted properly. If it is not inserted, correctly insert the CD-
ROM so that the label is facing up.
• The CD-ROM may be dirty. If it is dirty, wipe it with a soft, dry cloth.
• The CD-ROM may be scratched or bent. If scratched or damaged, replace the CD-ROM.
The unit does not operate properly.
Check to see whether the internal cable is connected properly. If it is not connected, correctly connect
the internal cable.

9.2.2 Error Messages

■ POST Error Messages
This section explains error messages of Power On Self Test: a device check performed during the server
startup (POST).
If an error occurs during POST, the following messages are displayed.
When checking/changing the settings of the BIOS Setup Utility, refer to "8.2 BIOS Setup Utility"
( Pg.217).
For instructions on checking peripheral connections, refer to "Start Guide".
For details on installing internal options, refer to "Chapter 7 Installing Internal Options" ( Pg.183).
Failure Fixed Disk
Stuck Key
Keyboard error
Keyboard controller error
System RAM Failed at offset: ********h
Shadow RAM Failed at offset: ********h
Extended RAM Failed at address line: ****h
Memory type mixing detected
256
table: List of POST Errors
Message
Description
IDE device error. Confirm the [Parallel ATA] setting on the
[Main] menu of the BIOS Setup Utility. If the message still
appears, the baseboard must be replaced. Contact an office
listed in the "Contact Information" of "Start Guide".
Keyboard error.Check whether the keyboard is connected
properly. If the message still appears, the keyboard must be
replaced.
Keyboard controller error. Release any keys held down on the
keyboard. If the message still appears, the baseboard must be
replaced. Contact an office listed in the "Contact Information"
of "Start Guide".
Memory error. Power off the server and turn it back on. If the
message still appears, check the error log and replace the faulty
memory module.
The installation configuration of the memory is wrong. Verify
that the same type of memory modules are installed in the slots
of the same bank. If the message displays even though the
installation is correct, replace the memory module.