Venting Arrangements; Allowable Horizontal Terminations For Gem54-Lpg/Ulpg - Regency GEM54-NG Owners & Installation Manual

Hide thumbs Also See for GEM54-NG:
Table of Contents

Advertisement

The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90
Note: Must use optional rigid pipe adapter (Part# 770-994) when using Rigid Pipe Venting Systems.
18
16
14
12
10
8
6
4
2
0
VENT RESTRICTOR SETTING:
Vent restrictor factory set, no adjustment required unless otherwise indicated.
Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting of Set 1 to
Set 3 if required.
Note: Regency
Direct Vent System (Flex) is only approved for horizontal terminations.
®
Maintain clearances to combustibles as listed in "Clearances" section
Horizontal vent must be supported every 3 feet (0.9m).
Firestops are required at each floor level and whenever passing through a wall.
A wall thimble is mandatory for all horizontal terminations due to high temperatures.
Regency Gemfire™ Gas Fireplace

VENTING ARRANGEMENTS

ALLOWABLE HORIZONTAL TERMINATIONS FOR GEM54-LPG/ULPG

0
2
4
Vent Restrictor
on Set 3
44 (1118mm)
Minimum Height
Requirement
Horizontal (Feet)
6
8
10
Vent Restrictor
on Set 1
(factory setting)
INSTALLATION
(two 45
elbows equal one 90
o
o
14
16
12
"THIS UNIT MUST ALWAYS
TERMINATE / VENT
DIRECTLY TO THE OUTDOORS."
elbow).
o
18
20
21