INSTALLATION
These venting systems, in combination with the Gem54, have been tested and listed as a direct vent system by AGA. The location of the termination
cap must conform to the requirements in the Vent Terminal Locations diagram from the "Exterior Vent Termination Locations" section.
FPI Direct Vent (Flex) System Termination Kits include all the
parts needed to install the Gem54 using a flexible vent.
FPI Kit #
Length Contains:
#946-615
4 Feet
1)
8" (203mm) flexible liner (Kit length)
(1.2 m)
2)
5"(127mm) flexible liner (Kit length)
3)
spring spacers
4)
#946-618
6 Feet
thimble
5)
AstroCap termination cap
(1.8 m)
6)
screws
7)
tube of Mill Pac
#946-616
10 Feet
8)
plated screws
(3 m )
9)
S.S. screws #8 x 1-1/2" (38mm) drill
point
10) vinyl siding standoff
16

VENTING ARRANGEMENTS

HORIZONTAL TERMINATION (FLEX)

Regency
®
Wall Thimble
(Mandatory in all
Horizontal T erminations)
5" dia. flue pipe
8" dia.
Flue pipe
Direct Vent System
Vinyl Siding
Standoff
AstroCap XL
Termination Cap
(Part #946-623/P)
spring spacer
Notes:
1) Liner sections should be continuous without any joints
or seams.
2) Only Flex pipe purchased from FPI may be used for Flex
installations.
3) Horizontal vent must be supported every 3 feet (0.9m).
4) A wall thimble is mandatory for all horizontal terminations
due to high temperatures.
Vent Guard - if required*