7) Remove bottom cover by undoing 3 screws securing it to the firebox
base, lift up and out.
Aerial View of the inside of the unit shown.
8) Disconnect the ON/OFF connector wires from the valve.
ON/OFF Connector Wires
9) Disconnect the DC Sparker leads at the valve.
Regency Gemfire™ Gas Fireplace
DC Sparker Lead
10) Unplug the Ignitor wire from the DC Sparker.
Ignitor Wire
11) Remove the valve tray by undoing 12 screws.
12) Slightly lift out valve tray.
13) Disconnect the inlet gas line.
14) Replace valve and reverse steps.