Check The Pressure Of The Heating Expansion Vessel; Cleaning The Domestic Hot Water Exchanger; Checking The Flue Expulsion Pipe; Combustion Analysis Check - Biasi Advance Plus 25C ERP User Manual And Installation Instructions

Wall hung, fanflue, roomsealed, high efficiency gas boiler
Hide thumbs Also See for Advance Plus 25C ERP:
Table of Contents

Advertisement

Fig. 9.12
Attention, to reassemble repeat
the operations carried out in re-
verse order. Be careful not to
damage the OR gasket of the
gas pipe when inserting the pipe
in Air box.
After any service operation on
the components of the gas cir-
cuit check all the connections
for gas leaks.
9.7
Check the pressure of the
heating expansion vessel
Drain the heating circuit as described in
section "Emptying the c.h. system" to page
78 and check that the expansion vessel
pressure is not less than 1 bar.
If the pressure is less, see to correct pres-
surisation.
9.8
Cleaning the domestic hot
water exchanger
Descaling the domestic hot water exchang-
er will be valued by an approved Service
Engineer, who will carry out any cleaning
using specific products.
- 80 -
MAINTENANCE
9.9
Have the integrity of the flue outlet pipe air
intake pipe, checked periodically, at least
once a year. For all the above maintenance
operations it is advisable to call an approved
Service Engineer.

9.10 Combustion analysis check

It is recommended that a combustion analy-
sis check is made. Remove the plug as indi-
cated in Fig. 9.13 and carry out combustion
analysis check and adjustment if necessary
as described in the section Gas valve - Ad-
justment of the Service manual.
Fig. 9.13
• Activate the "chimney sweep function" at
maximum heating power (see "Setting the
boiler chimney sweep function" on pag.
82).
• Make sure that the ambient thermostat is
in the position "call for heat".
• Withdraw an abundant amount of d.h.w.
by opening the faucets.
• Check the combustion of the boiler using
the outlets located on the flue tubes (Fig.
9.13) and compare the data measured
with that following.
Checking the flue expulsion
pipe
Flue analy-
sis points

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Advance plus 35c erpAdvance plus 30c erp

Table of Contents