4.3

Hydraulic specifications

The hydraulic specifications represents the
pressure (available head for the central
heating system) as a function of the flow
rate.
Model Advance Plus 25C ERP
Pression (bar)
0,50
0,45
0,40
0,35
0,30
0,25
0,20
0,15
0,10
0,05
0,00
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500
Fig. 4.3
Models Advance Plus 30C ERP - Advance
Plus 35C ERP
Pression (bar)
0,50
0,45
0,40
0,35
0,30
0,25
0,20
0,15
0,10
0,05
0,00
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500
Fig. 4.4
The boiler load loss has already been re-
moved.
Flow rate with closed thermostatic
valves
The boiler is equipped with an automatic
by-pass, which protects the condensing pri-
mary exchanger.
In case of excessive reduction or total stop-
ping of water circulation in the heating plant
due to the closing of thermostatic valves or
circuit elements valves, by-pass ensures a
TECHNICAL INFORMATION
Flow (l/h)
Flow (l/h)
minimum water circulation inside the con-
densing primary exchanger.
The by-pass is calibrated to a differential
pressure of about 0.3-0.4 bar.
4.4

Expansion vessel

Note: this boiler is designed for opera-
tion only in a sealed central heating sys-
tem.
The height difference between the pressure
relief valve and the highest point in the sys-
tem may be 10 m at most.
For greater differences, increase the pre-
load pressure in the expansion vessel and
the system, when cold, by 0.1 bar for each
additional 1 m.
Total capacity
Pre-load pressure
Useful capacity
Maximum volume of water in
the system *
Fig. 4.5
* Where conditions are:
• Average maximum temperature of the
system is 85 °C
• Initial temperature when filling up the sys-
tem is 10 °C
For
systems
greater then the one indicated in
the above table, an additional
expansion vessel must be pro-
vided.
l
7,0
kPa
100
bar
1,0
l
3,5
l
109
with
volumes