Setting The Pump Post-Circulation - Biasi Advance Plus 25C ERP User Manual And Installation Instructions

Wall hung, fanflue, roomsealed, high efficiency gas boiler
Hide thumbs Also See for Advance Plus 25C ERP:
Table of Contents

Advertisement

Press button
window (Fig. 7.26).
Fig. 7.26
It is possible to change the value using but-
tons
and
.
Press button
to exit from mode
(Fig. 7.26).
7.12 Setting the pump post-circula-
tion
The pump, in heating function, is set for a
post-circulation of about one minute at the
end of each heat request.
This time can be changed by a minimum of
zero to a maximum of four minutes by act-
ing on programming both from the panel
controls and the remote control.
• Enter in "programming mode" by pressing
keys 14 - 15 - 16 (Fig. 7.27) for 10 seconds
at the same time until the letters Pr that al-
ternate with code 01 are displayed on the
LCD display, indicating that "parameter
01" (Fig. 7.28) has been activated.
- 66 -
COMMISSIONING
to display the K REG
12
13
Fig. 7.27
Fig. 7.28
• Scroll the various parameters using keys
15 or 16 until the letters Pr that alternate
with code 11 are displayed on the LCD
display, indicating that "parameter 11"
(Fig. 7.29) has been activated.
Fig. 7.29
• Press keys 14 and 16 (Fig. 7.27) at the
16
15
14

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Advance plus 35c erpAdvance plus 30c erp

Table of Contents