Selecting The Reignition Frequency - Biasi Activ A 250V User Manual And Installation Instructions

Wall hung, fanflue, roomsealed, high efficiency gas boiler
Table of Contents

Advertisement

Programming using the REMOTE con-
trol
• Press button
for more than 3 seconds to
enter in
mode ( Fig. 7.28 ).
0
21
3
1
8
6
1 5
9
1
2
Fig. 7.28
and
• Press buttons
time to enter transparent programming
( Fig. 7.29 ).
Fig. 7.29
• Press buttons
the "PM11" program of the pump post-
circulation ( Fig. 7.30 ).
Fig. 7.30
- 64 -
COMMISSIONING
at the same
or
to display
• To modify the programmed SET, act on
buttons
or
programmed number to fl ash ( Fig. 7.31 ).
Each step increased or decreased corre-
sponds to 1 second.
Fig. 7.31
• To exit programming, press button .
7.12 Selecting the reignition fre-
quency
When the boiler functions in normal on/off
heating mode, the minimum time between
two ignitions is set at three minutes (re-igni-
tion frequency).
This time can be changed by a minimum of
zero to a maximum of eight and a half min-
utes by acting on programming both from
the panel controls and the remote control.
• Enter the "programming mode" by press-
ing keys 9 - 10 - 11 ( Fig. 7.32 ) for 10 sec-
onds at the same time until the letters Pr
that alternate with code 01 are displayed
on the LCD display, indicating that "pa-
rameter 01"( Fig. 7.33 ) has been activated.
and wait for the