Model Advance Plus 25C ERP
Nominal heat input
(A) (E)
Nominal efficency
Combustion efficency
Air index
Flue gas CO
content
2
Flue gas O
content
2
Flue gas CO content
Flue gas temperature
Values refer to tests with a an 80 mm double exhaust
split by 1 + 1 m and natural gas G20 and a supply /
return heating temperature of 60°/80°C.
Fig. 9.14
Model Advance Plus 30C ERP
Nominal heat input
(A) (E)
Nominal efficency
Combustion efficency
Air index
Flue gas CO
content
2
Flue gas O
content
2
Flue gas CO content
Flue gas temperature
Values refer to tests with a an 80 mm double exhaust
split by 1 + 1 m and natural gas G20 and a supply /
return heating temperature of 60°/80°C.
Fig. 9.15
Model Advance Plus 35C ERP
Nominal heat input
(A) (E)
Nominal efficency
Combustion efficency
Air index
Flue gas CO
content
2
Flue gas O
content
2
Flue gas CO content
Flue gas temperature
Values refer to tests with a an 80 mm double exhaust
split by 1 + 1 m and natural gas G20 and a supply /
return heating temperature of 60°/80°C.
Fig. 9.16
MAINTENANCE
The values in the tables are measured at
the nominal useful power with factory cali-
bration.
kW
20,0
%
97,4
%
97,6
9.11 Checking the condensate
n
1,2
%
9,2 - 9,8
The condensate drain pipe 34 (Fig. 9.17)
%
3,9
does not require any particular mainte-
nance but just check:
ppm
139
• That no solid deposits have formed, if so
°C
76,0
remove them.
• That the condensate drain piping is not
clogged.
Unscrew the plug to clean inside the pipe.
kW
25,0
%
97,4
%
98,2
n
1,2
%
9,2 - 9,8
%
3,9
ppm
75
°C
74,0
kW
30,0
%
98,2
%
98,3
n
1,2
%
9,2 - 9,8
Fig. 9.17
%
3,9
ppm
160
°C
81,6
9.12 Visual inspection of appliance
Visually inspect all water joints, seals and
connections for any evidence of leakage
and retighten, grease or replace them as
necessary.
drain pipe
34
- 81 -