7 - 12 Symbol MS4404/MS4407 Integration Guide

LED Illumination

Parameter # F0h, ADh
Select whether to use internal LED illumination (provided by the Symbol MS440X), external illumination (provided
outside the Symbol MS440X), or both.
This parameter only applies for decoding if
Image Capture Illumination on page 7-9
disabled, all illumination is off for that mode, regardless of this LED Illumination setting.
Internal Illumination
Internal and External Illumination

Snapshot Mode Timeout

Parameter # F0h, 43h
This parameter sets the amount of time the imager remains in Snapshot Mode. The imager exits Snapshot Mode
upon a trigger event, or when the Snapshot Mode Timeout elapses. To set this timeout value, capture the bar code
below followed by a bar code from
seconds; values increment by 30. For example, 1 = 60 seconds, 2 = 90 seconds, etc.
Snapshot Mode Timeout
Decoding Illumination on page 7-6
is enabled. If Decoding Illumination or Image Capture Illumination is
(00h)
(02h)
Appendix D, Numeric Bar
is enabled, or for image capture if
*External Illumination
(01h)
Codes. The default value is 0 which represents 30