Exposure Time - Motorola Symbol MS4404 Integration Manual

Miniscan imager
Hide thumbs Also See for Symbol MS4404:
Table of Contents

Advertisement

Exposure Time

Parameter # F4h, F0h, 38h
This parameter is only available when Image Capture Autoexposure is disabled. Exposure Time controls the
amount of time the CCD is allowed to collect light, much like the shutter speed for a camera. Generally, the brighter
the environment, the lower the exposure time. Set the manual exposure time to one of the following values: 5 ms,
10 ms, 15 ms, 20 ms, 25 ms, or 30 ms. Increasing the exposure time past 20 ms in a handheld application
increases the risk of blurring the image due to hand jitter.
5 ms
(004Fh)
15 ms
(00ECh)
25 ms
(018Ah)
Imager Preferences 7 - 11
*
10 ms
(009Dh)
20 ms
(013Bh)
30 ms
(01D8h)