11. To have the new NVM setting applied to the system, select Reboot Now. Otherwise,
select Cancel.
12. Run your print job.
Note
If the paper width in the job conflicts with the NVM width setting of the fuser, a Fuser
Type Mismatch error message displays and the job will not print. Either cancel the
job or replace the fuser type.
Note
After running your print job, switch off the NVM feature; this will ensure that the
press runs at maximum efficiency and will prevent paper jams.

Resetting the HFSI Counter

Many of the components of the press should be replaced at set print intervals. Each item
that requires regular maintenance or replacement has its own counter and a maximum
number of prints recommended between the maintenance task. Once a counter has
reached its usage limit, the system displays a message that the component needs to be
replaced. The status of the consumable is also shown on the Supplies/Consumables
screen from the Home button.
After replacing the customer-replaceable unit (CRU), the system administrator will need
to record the service by resetting the HFSI counter for the item at the press touch screen.
Note
This manual HFSI reset procedure does not need to be performed after replacing the
Drum Cartridges, Dry Ink/Toner Cartridges or Waste Dry Ink/Toner Container. The system
will automatically update the HFSI counter for those CRUs.
1. At the press, log on as administrator.
2. Press the Tools button on the press Control Panel.
3. From the screen that displays, select the Tools icon.
4. Select System Settings > Common Service Settings > Maintenance.
5. Use the up/down scroll arrows to access the next few Maintenance screens.
6. Select the Technical Key Operator icon.
7. From the screen that displays, select the row with the consumable part name that
corresponds with the newly-replaced component.
8. Select Reset Current Value.
The system resets the HFSI to 0 and saves the new value to the record log.
9. Verify that the Consumables screen has been reset and the status of the part is now
at 100%.

Initializing the Hard Disk

1. Log in as the administrator.
2. Press the Tools button on the press Control Panel.
Xerox
®
Versant 2100 Press
System Administration Guide
Common Service Settings
6-19