Begin the vent system installation by selecting the type of venting
to be installed and the path that it will take. Verify that clearances
are met throughout the path of the venting system. Determine if the
fireplace is to be vented vertically or horizontally.
NOTE: Unit requires 12 inches of rise before elbow, as well
as 2 inches of clearance around first 12 inches of pipe.
90° ELBOW
OR
45° ELBOW
90° ELBOW
CEILING FIRE STOP
WALL STRAP
PIPE LENGTH
Figure 15
Use one of the following 4 x 6-5/8 vent systems:
Simpson Duravent® DVA-H2
Simpson Duravent® GS
American Metal Products
Selkirk Direct-Temp®
Security Secure Vent®
Empire Flexvent Kit DVVK-4F, refer to page 32 - 33.
Or the following 4 x 6-1/2 vent system:
Metal Fab Sure Seal® (Note: Starter Adaptor Pipe required)
35919-4-1015
VENT SYSTEM IDENTIFICATION
Special Venting Components (Simpson Duravent)
See Empire Comfort Systems Retail Price List for Simpson Duravent part numbers
and pricing.
DVVK-4FV
DVVK-4VP
DVVK-4TP
DVVK-4TSP
SPECIAL VENT SYSTEMS
WALL THIMBLE
HORIZONTAL
TERMINATION
(MAXIMUM OF
THREE 90 ELBOWS
Special DV Vent Kits
Available from Empire Comfort Systems, Inc. dealers
Vertical Flex Vent Kit 4-in x 7-in
Direct-Vent Fireplace Vent Kit - Vertical.
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 8 to
11 inch wall thickness, Includes SD-911, SD-985, SD-990 and
SD-942
Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 5 to
7 inch wall thickness, Includes SD-908, SD-985, SD-990 and
SD-942
VERTICAL
TERMINATION
(MAXIMUM OF
THREE 90 ELBOWS)
STORM COLLAR
ROOF FLASHING
Page 11