Begin the vent system installation by selecting the type of venting
to be installed and the path that it will take. Verify that clearances
are met throughout the path of the venting system. Determine if the
fireplace is to be vented out the top.
NOTICE: Unit requires 12 inches of rise before elbow, as well as 2
inches of clearance around first 12 inches of pipe.
90° ELBOW
OR
45° ELBOW
90° ELBOW
CEILING FIRE STOP
WALL STRAP
PIPE LENGTH
Use one of the following 4 x 6-5/8 vent systems:
Duravent® DVA-H2
Duravent® GS
American Metal Products
Selkirk Direct-Temp®
Security Secure Vent®
Empire Flexvent Kit DVVK-4F, refer to page 37 - 38.
Page 28

VENT SYSTEM IDENTIFICATION

Figure 48

SPECIAL VENT SYSTEMS

WALL THIMBLE
HORIZONTAL
TERMINATION
(MAXIMUM OF
THREE 90 ELBOWS
Special Venting Components (Duravent)
See Empire Comfort Systems Retail Price List for Venting part
numbers and pricing.
Available from Empire Comfort Systems, Inc. dealers
DVVK-4FV
DVVK-4VP
DVVK-4TP
DVVK-4TSP
Or the following 4 x 6-1/2 vent system:
Metal Fab Sure Seal®
Adapter is required to use this vent
Contact Metal Fab
VERTICAL
TERMINATION
(MAXIMUM OF
THREE 90 ELBOWS)
STORM COLLAR
ROOF FLASHING
SPECIAL DV VENT KITS
Vertical Flex Vent Kit 4 inch x 7 inch
Direct-Vent Fireplace Vent Kit - Vertical.
Direct-Vent Fireplace Vent Kit for Top Vent,
Thru-the-wall, 8 to 11-inch wall thickness,
Includes SD-911, SD-985, SD-990 and
SD-942
Direct-Vent Fireplace Vent Kit for Top Vent,
Thru-the-wall, 5 to 7-inch wall thickness,
Includes SD-908, SD-985, SD-990 and
SD-942