Empire Comfort Systems MILLIVOLT DVCD32FP30N-4 Homeowner's Manual

Empire Comfort Systems MILLIVOLT DVCD32FP30N-4 Homeowner's Manual

Direct vent zero clearance gas fireplace heater series
Hide thumbs Also See for MILLIVOLT DVCD32FP30N-4:

Advertisement

INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
If you cannot reach your gas supplier,
call the fire department.
— Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
DANGER
A barrier designed to reduce the risk of burns from the
hot viewing glass is provided with this appliance and shall
be installed for the protection of children and other at-risk
individuals.
HOMEOWNER'S MANUAL
HOT GLASS
WILL
CAUSE BURNS.
DO NOT TOUCH
GLASS
UNTIL COOLED.
NEVER
ALLOW CHILDREN
TO TOUCH GLASS.
39669
DIRECT VENT
ZERO CLEARANCE GAS
FIREPLACE HEATER SERIES:
MILLIVOLT (MV)
DVCD(32,36,42)FP3(0,1)(N,P)-4
INTERMITTENT PILOT (IP)
DVCD(32,36,42)FP7(0,1)(N,P)-4
This appliance may be installed in an
aftermarket, permanently located,
manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
GAS-FIRED
UL FILE NO. MH30033
This fireplace is design
certified in accordance
with American National
Standard/CSA Standard
ANSI Z21.88/CSA 2.33
and by Underwriters
Laboratories as a Direct
Vent Gas Fireplace
Heater and shall be
installed according to
these instructions.
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Empire Comfort Systems MILLIVOLT DVCD32FP30N-4

  • Page 1 HOMEOWNER’S MANUAL 39669 INSTALLER: DIRECT VENT Leave this manual with the appliance. ZERO CLEARANCE GAS CONSUMER: FIREPLACE HEATER SERIES: Retain this manual for future reference. MILLIVOLT (MV) DVCD(32,36,42)FP3(0,1)(N,P)-4 WARNING INTERMITTENT PILOT (IP) FIRE OR EXPLOSION HAZARD DVCD(32,36,42)FP7(0,1)(N,P)-4 Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SECTION PAGE Combustible Material ..........................2 Homeowner Reference Information ......................2 Millivolt Standing Pilot Lighting Instructions (30) Series ................3 Millivolt Operating Instructions (30 Series) ....................4 Intermittent Pilot Lighting Instructions (FP7 Series) ................... 5 IPI Electronic System Operating Instructions (70 Series) ................6 Seasonal Shutdown ............................
  • Page 3: Millivolt Standing Pilot Lighting Instructions (30) Series

    MILLIVOLT STANDING PILOT LIGHTING INSTRUCTIONS (30 SERIES) FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. A. This appliance has a pilot which must be lighted by hand. C.
  • Page 4: Millivolt Operating Instructions (30 Series)

    MILLIVOLT OPERATING INSTRUCTIONS (30 SERIES) MILLIVOLT SYSTEM The standing pilot burns continuously even when the main burner is OFF. Follow the SAFETY and LIGHTING INSTRUCTIONS for standing pilot controls found in this manual and on labels found in the control area. During the operating season, leave the control valve knob in the “ON”...
  • Page 5: Intermittent Pilot Lighting Instructions (Fp7 Series)

    INTERMITTENT PILOT LIGHTING INSTRUCTIONS (FP7 SERIES) FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. This appliance has a pilot which can be lighted with the C.
  • Page 6: Ipi Electronic System Operating Instructions (70 Series)

    IPI ELECTRONIC SYSTEM OPERATING INSTRUCTIONS (70 SERIES) 5.25 VDC ELECTRONIC CONTROL VALVE NOTICE: The gas control has a manual HI/LO flame adjustment The electronic control valve system includes the ability to switch knob (regulator) that allows you to increase or decrease the the pilot from a standing pilot mode to an intermittent pilot mode.
  • Page 7: Seasonal Shutdown

    SEASONAL SHUTDOWN At the end of the heating season turn off the fireplace to prevent accidentall starting. Remove the barrier screen to gain access to the gas control valve, ON/OFF switch, and gas shut-off valve. Depending on the valve type the fireplace is equipped with, refer to either pages 3 or 5 for details on shutting off gas to the fireplace.
  • Page 8: Maintenance And Service

    MAINTENANCE AND SERVICE PLEASE NOTE WARNING It is normal for appliances fabricated of steel to give off some 1. The use of substitute glass will void all product warranties. expansion and/or contraction noise during the start up or 2. Care must be taken to avoid breakage of the glass. cool down cycle.
  • Page 9: Maintenance And Service

    MAINTENANCE AND SERVICE (CONT’D) Annual Inspection • Have the fireplace inspected annually before use. • More frequent inspection and cleaning may be required if the fireplace is installed in an area exposed to pet hair or dust, or to excessive lint from new carpeting or bedding materials. During The Annual Checkup, The Technician Will: •...
  • Page 10: Important Safety Information

    IMPORTANT SAFETY INFORMATION For the Homeowner • This fireplace must be installed and serviced by your dealer or a qualified service technician. Other than cleaning the glass and replacing the light bulbs, there are no user- serviceable components. • Keep the area around the fireplace clean and free of debris. This fireplace requires an unimpeded flow of air to circulate warm air.
  • Page 11: Annual Fireplace Inspection Checklist

    ANNUAL FIREPLACE INSPECTION CHECKLIST > ANNUAL INSPECTION DATE Inspect pilot and burner system and replace any damaged parts Check glass gasket and door for proper seal Check barrier screen for proper fit and structural integrity Check latches for proper operation and tensions Inspect log set/decorative media for debris and damage Clean dust and debris from fireplace...
  • Page 12: Safety Information For Users Of Propane Gas

    SAFETY INFORMATION FOR USERS OF PROPANE GAS Propane is a flammable gas which can cause fires and The odorant in escaped gas can adsorb or absorb onto or explosions. In its natural state, propane is odorless and into walls, masonry and other materials and fabrics in a room. colorless.
  • Page 13: Requirements For Massachusetts

    REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment 4. INSPECTION. The state or local gas inspector of the installed in every dwelling, building or structure used in side wall horizontally vented gas fueled equipment whole or in part for residential purposes, including those shall not approve the installation unless, upon owned or operated by the Commonwealth and where the inspection, the inspector observes carbon monoxide...
  • Page 14: Warranty

    WARRANTY Empire Comfort Systems Inc. warranties this hearth product to be free from defects at the time of purchase and for the periods speci- fied below. Hearth products must be installed by a qualified technician and must be maintained and operated safely, in accordance with the instructions in the owner’s manual.
  • Page 15: Appliance Service History

    APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed/Notes 39669-0-0618 Page 15...
  • Page 16 Empire Comfort Systems Inc. Belleville, IL If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. www.empirecomfort.com Page 16 39669-0-0618...

Table of Contents