MILLIVOLT STANDING PILOT LIGHTING INSTRUCTIONS (BP3 SERIES)
FOR YOUR SAFETY READ BEFORE LIGHTING
A. This appliance has a pilot which must be lighted by
hand. When lighting the pilot, follow these instructions
exactly.
B. Before lighting smell all around the appliance area for
gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.
What To Do If You Smell Gas
• Do not try to light any appliance.
• Do not touch any electrical switch;
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the
fire department.
1. Stop! Read the safety information above.
2. Set REMOTE/OFF/ON switch to OFF.
3. Turn off all electric power to the appliance (if applicable).
4. Lower bottom louver assembly.
5. Push in gas control knob slightly and turn clockwise
to "OFF."
Note: Knob cannot be turned from "PILOT" to "OFF" unless
knob is pushed in slightly. Do not force.
6. Wait ten minutes to clear out any gas. Then smell for gas,
including near the floor. If you then smell gas, STOP!
Follow "B" in the safety information above. If you do not
smell gas, go to the next step.
7. Find pilot - Follow metal tube from gas control. The
pilot is behind the burner on the right side.
8. Turn gas control knob counterclockwise
"PILOT."
GAS CONTROL KNOB SHOWN
IN "OFF" POSITION
1. Set REMOTE/OFF/ON switch to OFF.
2. Turn off all electric power to the appliance if service is
to be performed (if applicable).
3. Lower bottom louver assembly.
Page 36
If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
LIGHTING INSTRUCTIONS
THERMOCOUPLE
ELECTRODE
PILOT
TO TURN OFF GAS TO FIREPLACE
WARNING
C. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in
or turn by hand, don't try to repair it; call a qualified
service technician. Force or attempted repair may
result in a fire or explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of
the control system and any gas control which has
been under water.
9. Push in control knob all the way and hold in. Repeatedly
push the piezo ignitor button until the pilot is lit. Continue
to hold the control knob in the for about one minute
after the pilot is lit. Release knob, and it will pop back
up. Pilot should remain lit. If it goes out, repeat steps 5
through 9.
If the control knob does not pop up when released,
STOP and IMMEDIATELY call a qualified service
technician or gas supplier.
If the pilot will not stay lit after several tries, turn
the gas control knob to "OFF" and call your service
technician or gas supplier.
10. Turn gas control knob counterclockwise
"ON."
to
11. Close bottom louver assembly.
12. Turn on all electric power to the appliance (if applicable).
13. Set REMOTE/OFF/ON switch to desired setting.
THERMOPILE
REMOTE
OFF
ON
4. Push in gas control knob slightly and turn clock-
wise
5. Close bottom louver assembly.
to "OFF." Do not force.
to
35919-4-1015