Empire Comfort Systems DVCP36BP0N-2 Installation Instructions And Owner's Manual page 18

Direct vent zero clearance gas fireplace heater millivolt and intermittent pilot series
Table of Contents

Advertisement

Vent Pipe Clearance
For horizontal vent, maintain a minimum 2-in clearance to the bottom
and sides of the vent, and 3-in clearance to combustibles above
the vent pipe. See Figure 30.
VENT PIPE
2" MINIMUM CLEARANCE AROUND VENT PIPE
3" (75mm)
Top of
Vent
2" (50mm)
Framing - In the Wall
Fireplace framing can be built before or after the fireplace is set
in place. Framing should be positioned to accommodate wall
covering and fireplace facing material. The fireplace framing should
be constructed of 2 x 4 lumber. Refer to Figure 31 for minimum
framing dimensions.
CAUTION: MEASURE FIREPLACE DIMENSIONS AND VERIFY
FRAMING METHODS, AND WALL COVERING DETAILS
BEFORE FRAMING CONSTRUCTION BEGINS.
Note: For finishing to top of fireplace, refer to Figure 32.
Note: Minimum chase top to top of framing edge is 24-in.
Page 18
INSTALLATION (continued)
Figure 29
Combustibles NOT
allowed in shaded
area
4" Diameter flue
7" Diameter
intake vent
2" (50mm)
Figure 30
CAUTION
DVCP32
(Dimensions in inches)
A
47-1/4
B
34-3/4
C
17-1/4
Finishing
Finish the walls with the material of your choice. Figure 19 on
page 13 shows the minimum vertical and corresponding maximum
horizontal dimensions of mantels or other combustible projections
above the top front edge of the fireplace.
Only non-combustible materials may be used to cover the black
fireplace front.
When finishing the fireplace never obstruct or modify the air
inlet/outlet in any manner. Provide adequate clearances around
air openings into the combustion chamber.
If the joints between the finished wall and the fireplace surround
(top and sides) are sealed, a 300 Degree F minimum sealant mate-
rial must be used. These joints are not required to be sealed. Only
non-combustible material (using 300 Degree F minimum adhesive
if needed), can be applied as facing to the fireplace surround.
DVCP36
DVCP42
47-1/4
49-1/4
37-3/4
43-3/4
17-1/4
17-1/4
Figure 31
WARNING
CAUTION
35919-4-1015

Advertisement

Table of Contents
loading

Table of Contents