D-Link DGS-3324SRi User Manual page 160

High-density layer 3 stackable intelligent gigabit ethernet switch
Hide thumbs Also See for DGS-3324SRi:
Table of Contents

Advertisement

D-Link DGS-3324SRi Intelligent Stackable Gigabit Ethernet Switch
The following fields can be set:
Parameter
Time Interval [1s ]
Record Number
[200]
CrcError
UnderSize
OverSize
Fragment
Jabber
Drop
Show/Hide
Figure 6- 9. Rx Error Analysis window (table)
Description
Select the desired setting between 1s and 60s, where "s" stands for
seconds. The default value is one second.
Select number of times the Switch will be polled between 20 and 200. The
default value is 20.
Counts otherwise valid frames that did not end on a byte (octet) boundary.
The number of frames detected that are less than the minimum permitted
frame size of 64 bytes and have a good CRC. Undersize frames usually
indicate collision fragments, a normal network occurrence.
Counts packets received that were longer than 1518 octets, or if a VLAN
frame 1522 octets, and less than the MAX_PKT_LEN. Internally,
MAX_PKT_LEN is equal to 1522.
The number of packets less than 64 bytes with either bad framing or an
invalid CRC. These are normally the result of collisions.
The number of frames with lengths more than the MAX_PKT_LEN bytes.
Internally, MAX_PKT_LEN is equal to 1522.
The number of frames that are dropped by this port since the last Switch
reboot.
Check whether or not to display CrcError, UnderSize, OverSize, Fragment,
Jabber, and Drop errors.
145

Advertisement

Table of Contents
loading

Table of Contents