Use the following procedure to clear the deskphone of its administrative, user-assigned and options
values.
1. While the deskphone is on-hook and idle, press the following sequence of keys on the faceplate of
the deskphone:
Mute 2 7 2 3 8 2 5 3 2 7 # (Mute C R A F T C L E A R #)
!
Important:
2 7 2 3 8 is the default password. If you have changed that password by changing the
Important:
value of PROCPSWD, replace 27238 with the latest password.
Note:
Press the Mute button momentarily. Do not press this button while pressing other keys/
Note:
buttons.
The following text displays left-justified at the top of the display:
Clear all values?
*=no
2. If you do not want to clear all values, press * (no) to terminate the procedure and retain the current
values.
A screen displays the following prompt on the top line:
Are you sure?
*=no
#=yes
3. Press the * button to terminate the procedure without clearing the values. Press the # button to
clear all values to their initial default values.
A confirmation tone sounds and the following text displays left-justified at the top of the display:
Clearing values.
The deskphone is cleared to its "out of the box" state.

Disabling or enabling the Debug mode

Note:
The Debug mode is available only on the 1616 deskphone.
Note:
With Release 1.3.3, the Debug mode is available only if you change the default CRAFT
password. You can change the password to any value between 0000 to 9999999.