Toshiba Magnia 510D User Manual page 115

Hide thumbs Also See for Magnia 510D:
Table of Contents

Advertisement

Hardware Diagnostics
SCSI HDD TEST (HDD) Error Log
Status
01
03
04
05
09
0D
0E
80
81
82
83
84
85
86
87
89
8A
8B
8C
8E
E0
F0
FE
FF
Error name
CHECK CONDITION OR BAD
COMAND
DRIVE SELECTION FAILED
TARGET DRIVE BUSY
SCSI BUS TIME OUT
DMA BOUNDARY ERROR
COMMAND TERMINATED
QUEUE FULL
NO SENSE
RECOVERED ERROR
NOT READY
MEDIUM ERROR
HARDWARE ERROR
ILLEGAL REQUEST
UNIT ATTENTION
DATA PROTECT
VENDOR UNIQUE
COPY ABORTED
ABORTED COMMAND
EQUAL
MIS COMPARE
STATUS ERROR
NO DRIVE ERROR
NO DRIVE ERROR
DATA COMPARE ERROR
Hardware Diagnostics Program
Meaning
Bad command error
Drive selection error
Target drive is busy
Time out error of SCSI bus
DMA BOUNDARY occurred
Command terminated
Command queue is full
Sense data is invalid
Execution of the command has
correctly finished because of
recovery treatment.
Condition does not satisfy for the
command execution
Error occurred because of the
failure of a medium
Hard error that is impossible to
recover occurred during command
execution
CBD is illegal
Function of hard disk drive has
been changed
Data protection error
Unique error of disk maker
COPY command stopped
Execution of a command is
correctly stopped
Comparing result of the search
data command is satisfied
Comparing command error
Status error
Target drive has not been found
Target drive has not been found
Data comparing error
115