Removal and Replacement Procedures
5. Remove both hot-plug power supplies. See the "Hot-Plug Power Supplies" section in this
chapter.
6. Remove the interconnect tray from the enclosure. See the "Interconnect Tray" section in
this chapter.
7. Rotate the quarter-turn posts on the Integrated Administrator module 90 degrees (1).
8. Remove the two screw locks with the tool provided in your spares kit (2).
9. Lift the Integrated Administrator module off the anchor pins (3).
10. Remove the Integrated Administrator module from the interconnect tray (4).
Figure 2-16: Removing the Integrated Administrator module from
the interconnect tray
Reverse steps 1 through 10 to replace the Integrated Administrator module.

Enclosure Status Assembly

To remove the enclosure status assembly:
1. Power down each server blade. See the "Powering Down a Server Blade" section in this
chapter.
2. Power down the enclosure. See the "Powering Down the Enclosure" section in this
chapter.
3. Disconnect all cables and power cords from the AC power source.
4. Disconnect all cables and power cords from the enclosure rear panel.
5. Remove all server blades and server blade blanks. See the "Removing a Server Blade"
and the "Removing a Server Blade Blank" sections in this chapter.
2-22
HP CONFIDENTIAL Codename: Kerr Part Number: 249066-004 Last Saved On: 5/12/03 3:00 PM
HP ProLiant BL e-Class System Maintenance and Service Guide