IBM eServer 130 xSeries User Reference Manual page 114

Hide thumbs Also See for eServer 130 xSeries:
Table of Contents

Advertisement

Table 15. Diagnostic error messages.
Code
Function
075
Microprocessor
175
System thermal
180
Status display
201
System memory
100
IBM xSeries 130: User's Reference
Result
Failed
VRM corresponding to Microprocessor in socket xyz
is defective
(where xyz identifies the microprocessor whose
VRM is causing the error message)
VRM corresponding to Microprocessor in socket ID
xyz is not installed
(where xyz identifies the microprocessor whose
VRM is causing the error message)
Failed
Fan # n
(where n is the number of the failing fan)
Temperature sensed on processor board is out of
range
Failed
Any failure message
Failed
DIMMs in location DIMM n
(where n is the number of the socket that contains
the failing DIMM)
Test setup error: Corrupt BIOS in ROM
Test setup error: Corrupt DMI BIOS, information in
BIOS is not as expected
Text message
Action
Replace the VRM.
If the problem remains,
call for service.
Install a VRM.
If the problem persists,
call for service.
Replace the indicated
fan.
Call for service.
Call for service.
1.
Reseat the failing
DIMM.
2.
If the problem
remains, replace
the DIMM.
If the problem
persists, call for
service.
If your appliance server
does not have the latest
level BIOS installed,
update the BIOS to the
latest level.
If the problem persists,
call for service.

Advertisement