Table 14. POST error messages.
POST message
201
An error occurred during the memory controller test. This error can be caused by:
Action: 1.
229
An error was detected in the L2 cache of one of the microprocessors.
Action: 1.
289
An error occurred during POST memory tests, and a failing DIMM was disabled.
Note: You can use the appliance server with decreased memory.
Action: 1.
If the problem persists, call for service.
301 303
An error occurred during the keyboard and keyboard controller test. These error messages also
might be accompanied by continuous beeping.
Action: Ensure that:
Running the diagnostic tests can isolate the appliance server component that failed, but you must
have your system serviced. If the error message remains, call for service.
Note: If you just connected a new mouse or other pointing device, turn off the appliance server
602
Invalid diskette boot record
Action: 1.
If the problem persists, call for service.
604
An error occurred during a diskette drive test.
Action: 1.
662
A diskette drive configuration error occurred.
Action: If you removed a diskette drive, make sure that the diskette drive setting is correct in the
If the problem persists, call for service.
90
IBM xSeries 130: User's Reference
Incorrectly installed memory
A failing memory module
A system board problem
If you just installed memory, verify that the new memory is correct for your
appliance server. Also verify that the memory is installed and seated correctly.
2.
If the problem persists, call for service.
If you just installed a microprocessor, verify that the microprocessor is installed and
seated correctly.
2.
If the problem persists, call for service.
If you just installed memory, verify that the new memory is correct for your appliance
server. Also verify that the memory is installed and seated correctly. Start the
Configuration/Setup Utility program and select Memory Settings from the
Advanced Setup menu to enable the DIMM.
2.
If the problem remains, replace the failing DIMM.
Nothing is resting on the keyboard and pressing a key.
No key is stuck.
The keyboard cable is connected correctly to the keyboard and to the correct
connector on the appliance server.
and disconnect that device. Wait at least 5 seconds; then, turn on the appliance server. If
the error message goes away, replace the device.
Replace the diskette.
2.
If the problem persists, make sure that the diskette drive cables are correctly and
securely connected.
3.
If the problem remains, replace the diskette drive.
Verify that the Configuration/Setup Utility program correctly reflects the type of
diskette drive that you have installed.
2.
Run the diagnostic tests. If the diagnostic tests fail, call for service.
Configuration/Setup Utility program. If the setting is not correct, change it.