Removing the used lamp

1. Turn the power off and disconnect the
projector from the power outlet. Turn off
all connected equipment and disconnect all
other cables.
2. Remove the screws on the lamp cover (A),
and slide the lamp cover as shown (B).
B
A
3. Loosen the two captive screws on the lamp
module (A). Lift the module handle up as
shown (B).
A
B
4. Pull firmly on the module handle in the
direction shown to remove the lamp.
Pulling it too quickly may cause the lamp to break
and scatter broken glass in the projector. To reduce
the risk of injuries to fingers and damage to internal
components, use caution when removing lamp glass
that has shattered.
Do not place the lamp in locations where water might
splash on it, children can reach it, near or above heat
sources, or near flammable materials.
Do not insert your hand into the projector when the
lamp is removed. If you touch the optical components
inside, it could cause blurred images.
5. Reverse steps 1 to 3 to install the new lamp
module(s).
new lamp
6. Tighten the screws securing the lamp box.
Reconnect the lamp connector.