[E] Switching regulator unit (PS)
(1)
Take off the left cover.
P.2-19 "[C] Left cover"
(2)
Disconnect 15 connectors.
Note:
The number of connectors to be discon-
nected is 15 when the following options are
installed.
A: Paper Feed Controller (GH-1060)
B: Fax Kit (GD-1220/1221)
Note:
Connect the connectors to the correct faston
terminals on the switching regulator board.
Connector
F. Red
-
E. Blue
-
D. White
-
C. White
-
B. White
-
A. White
-
(3)
Remove 2 screws, slide the switching regula-
tor unit with the whole case slightly to the
front, and then lift it up to take it off.
e-STUDIO167/207/237
OUTLINE OF THE MACHINE
Harness
Black-thick
White-thick
Black-thin
Red-thin
Red-thick
White-thick
2 - 26
08/06
A
B
Fig. 2-30
Fig. 2-31
Switching regulator unit
Fig. 2-32