Updating the Firmware on Print Server Card

Updating of the firmware is performed on a computer connected in network with Print Server Card. Install the F-ROM utility to
perform updating of the firmware. There are 2 attached utilities, for IPX and FTP connection to update the firmware.
7.2.1

Flash Update v1.XX for IPX connection

This program uses an IPX connection to download and install a new executable code version into the your print server or Print
Server Card. To run this program, both your computer and the Print Server Card must have IPX (Novell) enabled.
1.
Double-click on the icon of "Flash_up.exe" to start Flash Update utility.
You must have supervisor rights on a Novell Server to use this program.
2.
Select the Print Server Card from the list showed all the print server and Print Server Card units on your network.
The units are listed by 3-letter code, follows by a 6-digit serial number.
3.
Locate and then select the update file you want to use to update the firmware.
4.
Click on [OK].
Updating firmware is started.
5.
The result of the download to the Print Server Card is listed.
6.
"Successful" appears next to the Print Server Card's serial number if the updating is successfully completed.
7.2.2

FTP Download Utility v1.XX for FTP connection

This program uses an FTP connection to download and install a new executable code version into your print server or Print
Server Card. To run this program, both your computer and the Print Server Card must have TCP/IP enabled and must have
been assigned a valid IP address.
Password for FTP Download : sysadm
1.
Double-click on the icon of "Ftpdl.exe" to start FTP Download utility.
2.
Go to the File menu and click on [Download].
The Select a file to download screen appears.
3.
Locate and then select the update file you want to use to update the firmware.
4.
Click on [OK].
The IP Address screen appears.
5.
Enter the IP Address assigned to the machine, and then click on [OK].
If the computer and printer are on different subnets, subnet masks and default routers (gateway address) may
also need to be entered.
The Password screen appears.
6.
Enter the serviceman password, then click on [OK].
The serviceman password is "sysadm". The entered password is described with "∗".
7.
Updating firmware is start.