Oki C911 Maintenance Manual page 68

Hide thumbs Also See for C911:
Table of Contents

Advertisement

Oki Data CONFIDENTIAL
Table 4-1-3 Initializing
Online
Inspection
Panel display
indicator
lamp
Initializing
Off
Off
Initializing
Off
Off
EEPROM Reset
Off
Off
RAM Check
Off
Off
nnn%
Wait a Moment
Off
Off
Network Initializing
Flash Memory Format
Off
Off
%STORAGE%
Off
Off
Formatting
Checking File System
Off
Off
Erasing Disk
Off
Off
nnn%
45530603TH Rev.2
Details
It is displayed until the system display language
is determined immediately after the power is
turned on.
Indicates the controller side is initializing.
Indicates that the EEPROM of the controller side
is being reset.
The conditions for resetting the EEPROM are as
follows:
• Change of CU ROM (when disagreement of the
CU F/W version is detected)
• Change of destinations
• Forced initialization of the EEPROM (Factory
Maintenance menu)
• OEM setting by PJL commands
Indicates that RAM is being checked.
Percentage of the checked portion against the
total capacity is shown in the second line.
The network is in initialization.
Indicates that the flash memory is being
formatted. If a resident/optional flash memory
that is not yet formatted is detected, it is
displayed when the menu item [Format Flash
ROM] is selected from [Maintenance Menu] of
the Factory Maintenance menu. Because the
above processing is secret to users, this status
does not occur in a user environment.
Indicates the HDD/FLASH is being formatted
(initialized).
Indicates that the HDD file system is being
checked.
The checking process for the file system can be
started from [Others Setup] - [Storage Common
Setup] - [Check File System] of Admin Setup.
Indicates that the hard disk is being erased.
The erasure process for the hard disk can be
started from [Others Setup] - [HDD Setup] -
[Erase HDD] of Admin Setup.
nnn
The percentage of erased space
Online
Inspection
Panel display
indicator
lamp
Checking Sectors
Off
Off
nnn%
PU Flash Error
Off
Off
Communication Error
Off
Off
Status Mode
Off
Off
4. TROUBLESHOOTING PROCEDURE
Details
Indicates that HDD sectors are being checked.
The sector check process can be started from
[Others Setup] - [Storage Common Setup] -
[Check All Sectors] of Admin Setup.
nnn
The percentage of checked portions
Indicates that the PU firmware has not started up
successfully. The status changes to Priority 251
(*** Flash Error) when initialization is completed.
This error can occur in a user environment. If
this error occurs, maintenance by a maintenance
engineer is required (as in the case of S/C).
Indicates that communication with the PU
firmware during initialization has failed. This error
can not occur in a user environment.
If this error occurs, maintenance by a
maintenance engineer is required (as in the case
of S/C).
Indicates that the printer is started in the normal
Online mode.
Once the printer is started in this mode, it
processes data (jobs) sent from an external
device (a host) even when an error occurs after it
becomes online (Ready).
An error message or warning is displayed on the
panel.
To enter this mode, switch on the power while
holding down <OK> + <Back> + <Down>
buttons. Because the above button operation is
secret to users, this status does not occur in a
user environment.
4-23

Advertisement

Table of Contents
loading

This manual is also suitable for:

C931C941

Table of Contents