1. Enter the self-diagnostic-mode(Level1) and, until the following message
appears, press the MENU or MENU button.
MeDia Wt aDJUst Pa
2. Press the OK button. The following message appears. Press the MENU
MENU button until the intended option appears.
MeDia Wt aDJUst Pa
eDit tHicKness Data
3. Press the OK button. The test of the option displayed on the panel is performed.
<EDIT THICKNESS DATA is executed>
① When the above step 3 is performed, the following message appears. Press the
MENU or MENU button until the intended option appears.
saMPLe Page
② By pressing the OK button while an item you wish to set is displayed, the option
can be set. Enter a value you wanted to set with the following SW operation.
saMPLe Page
P=*
Pressing the MENU button displays the next test result.
Pressing the MENU button displays the preceding test result.
③ Press the BACK button to return to the ① .
④ Repeat the steps ① to ③ as necessary.
45530603TH Rev.2
<WEIGHT SCAN ADJ EXEC is performed>
① The sensitivity adjustment of the media weight detection sensor starts and the
lower line of the display starts blinking.
② When the sensitivity adjustment is completes, the upper line of the display
shows the result of the test (OK or an error name), the lower line of the display
shows '****RESULT'.
or
oK
WeigHt scan aDJ RsLt
Remark: The following message appears while the printer is initialized or
issues an alarm or when the cover is open.
ng
WeigHt scan aDJ RsLt
Pressing the MENU button displays the next test result.
Pressing the MENU button displays the preceding test result.
Press the BACK button to return to step 2 (WEIGHT SCAN ADJ RSLT).
③ Pressing the CANCEL button during the test cancels the test, restoring the state
of step 2.
<WEIGHT SCAN ADJ RSLT is performed>
Same button operation as of WEIGHT SCAN ADJ EXEC.
4. Repeat steps 2 and 3 as necessary.
5. Press the BACK button to end the test (the state is restored to the step1).
MEDIA WT ADJUST PA Selection Items
SUB MENU
Details
EDIT THICKNESS
Number of sheets fed,
DATA
media weight setting
WEIGHT SCAN ADJ
Execution of media
EXEC
weight detection
mechanical adjustment
WEIGHT SCAN ADJ
Refer to the result of
RSLT
media weight detection
mechanical adjustment.
5. MAINTENANCE MENUS
Handling of results
For displayed items, refer to the table 「
EDIT
THICKNESS DATA Selection Items」
.
OK: Writes an adjustment value in EEPROM.
NG: Displays errors and updates RESULT
only.
For displayed items, refer to the table
「WEIGHT SCAN ADJ RESULT」.
5-41