ADDENDUM #1 Interior Masonry Chimney Conversions
Follow the requirements and use the equipment listed in the illustration to the right to install this
appliance into an interior masonry chimney.
Maximum vertical rise is 30'
Minimum vertical rise is 10'
Use the following restrictor positions:
Position 2 for heights between 10' and 14'
Position 3 for heights between 14' and 22'
Position 4 for heights between 22' and 34'
NOTE: these restrictor positions are based upon lab tests. The ideal restrictor position may vary slightly.
Travis Industries
Addenda
The entire chimney system
must be air-tight. Make sure to
seal the flashing, clean-out,
and thimble connection, and to
inspect the chimney.
Make sure the coaxial pipe
maintains a 1" clearance to any
combustible. The vent must be
sealed air-tight.
#990 90° Elbow
Co-Axial
Straight
Lengths
#991 High
Wind
Termination
Flashing
(included in
#934 Masonry
Conversion Kit
#711 Flex Liner
(4" dia.)
(or other UL 1777
Gas Liner)
Connector with
Cover (included
in #934
Masonry
Conversion Kit
4041220