Installation Addenda; Class A Chimney Conversion Kit; Interior Masonry Chimney Conversions - Lopi heritage Owner's Manual

Direct vent freestanding stove
Hide thumbs Also See for heritage:
Table of Contents

Advertisement

ADDENDUM #1 Class A Chimney
Conversion Kit
Simpson Duravent provides a conversion kit for those wishing to use an existing
wood stove chimney to vent this direct vent stove. The illustration below gives
an overview of this type of installation. See the instructions included with the kit
for details.
!
Do not exceed the maximum vertical rise (see the section "Approved Vent
Configurations" starting on page 10) allowable. Remember to set the restrictor
position to the correct position (based upon the vertical rise height).
!
The conversion kit does not work on interior masonry chimneys.
Chimney Conversion Kit A (# 931)
Metalbestos 6" I.D.
Security Chimneys 6" I.D.
Jackes-Evans 6" I.D.
Hart & Cooley 6" I.D.
Pro-Jet 6" I.D.
Chimney Conversion Kit B (# 932)
Simpson Dura-Vent 6" I.D.
Air-Jet 6" I.D.
Metal-Fab 6" and 7" I.D.
Amer. Metals 6" & 7" I.D.
Metalbestos 7" and 8" I.D.
Jackes-Evans 7" and 8" I.D.
Hart & Cooley 7" and 8" I.D.
Pro-Jet 7" and 8" I.D.
Security Chimneys 8" I.D.
Chimney Conversion Kit C (# 933)
Simpson Dura-Vent 7" and 8" I.D.
American Metals 8" I.D.
Air-Jet 8" I.D.
Metal-Fab 8" I.D.
American Metals 8" I.D.
Each Kit Contains:
Retro Connector
Retro Vertical Top
Additional Required Equipment:
4" Flex (#711 or U.L. 1777)
Termination (#991)
Co-Axial Sections
ADDENDUM #2 Masonry
Chimney or Fireplace
Conversions
Follow the requirements and use the equipment
listed in the illustration to the right to install this
appliance into an interior masonry chimney.
Maximum vertical rise is 38'
Minimum vertical rise is 10'
Use the following restrictor positions:
Position 1 for heights between 10' and 16'
Position 7 for heights between 16' and 38'
NOTE: these restrictor positions are based
upon lab tests. The ideal restrictor position may
vary.
Travis Industries

Installation Addenda

100-01135
Screw the Retro
Vertical Top to the
Flex Pipe
Type A Chimney
4" (100 mm)
Aluminum Flex
Pipe
Retro Connector
(screw to chimney)
Simpson Duravent Direct
Vent Pipe Sections
(use adjustable section)
Interior Masonry Chimney
The entire chimney system
must be air-tight. Make sure to
seal the flashing, clean-out,
and thimble connection, and to
inspect the chimney.
Make sure the coaxial pipe
maintains a 1" clearance to any
combustible. The vent must be
sealed air-tight.
#990 90° Elbow
Co-Axial Straight
Lengths
Standard Masonry Fireplace
The entire chimney system
must be air-tight. Seal the
connector cover and inspect
the chimney.
Make sure the coaxial pipe
maintains a 1" clearance to any
combustible. The vent must be
sealed air-tight.
35
Retro Vertical Top
(screw to chimney)
Cut the Flex Pipe to
the chimney height
plus 3" (75 mm)
Screw the Retro
Connector to the
Flex Pipe
#991 High Wind
Termination
Flashing (included in
#934 Masonry
Conversion Kit
#711 Flex Liner (4" dia.)
(or other UL 1777 Gas
Liner)
Connector with Cover
(included in #934 Masonry
Conversion Kit)
#991 High Wind
Termination
Flashing (included in
#934 Masonry
Conversion Kit)
#711 Flex Liner (4" dia.)
(or other UL 1777 Gas Liner)
Connector (included in #934
Masonry Conversion Kit)
secured and sealed to
block-off plate.
4 0 4 0 8 0 9