Hearth Stove Installation; Interior Or Exterior Masonry Chimney - Lopi Evergreen Owner's Manual

Wood stove
Hide thumbs Also See for Evergreen:
Table of Contents

Advertisement

14
Hearth Stove
Installation
NOTE:
This type of installation
requires a full reline
(positive connection).
Interior or Exterior
Masonry Chimney
NOT ALLOWED IN
CANADA UNLESS FULL
RELINE IS USED>.
NOTE:
This type of installation
requires a UBC approved
masonry connector or
other method approved by
the NFPA 211 Standard.
See Chimney Connector
Requirements on page 9
for further details.
WARNING:
We strongly recommend a
full reline (positive
connection) when venting
through a masonry
chimney. We also
recommend that a
minimum 914.1mm (3')
chimney be added to the
minimum system height
for every 304.8mm (1') of
horizontal run.
© Travis Industries
Stove Installation
NOTE: The entire fireplace and
chimney must be clean, undamaged,
and meet all local building codes (UBC,
etc.). Damage must be repaired prior to
installation. The chimney must be 15'
to 33' tall.
Combustible
Mantle
Floor Protection (See the
section "Floor Protection
Requirements" for more
details)
NOTE: the chimney must
have a clay tile liner. If it does
not, the installation must use
a positive connection (full
reline). The entire fireplace
and chimney must be clean,
undamaged, and meet all
local building codes (UBC,
etc.). Damage must be
repaired prior to installation.
The chimney must be 15'
(4.57M) to 33' (10.05M) tall.
See section "Stove Placement
Requirements" for minimum
clearances required.
Chimney connector sections
See the section
"Floor Protection
Requirements"
(for qualified installers only)
Min. 36"
Min. 18"
(457mm)
clearance to
ceiling
100-01438
Cap and flashing prevents
water from entering.
The liner must be
stainless steel connector
or flexible vent. Follow
the liner manufacturer's
instructions for installation
and support.
Airtight Insulated
Clean-Out
Remove damper or
wire it open
See the section "Stove
Placement
Requirements" for
minimum clearances
required.
Full Reline
Clay Liner
This type of
installation
requires a
UBC
approved
masonry
connector or
a factory built
(U.L. Listed)
wall thimble.
Make sure
the clean-out
seals in
place.
4160303