Lopi allegiance Owner's Manual page 34

Direct vent
Table of Contents

Advertisement

Optional Equipment
4
Remove the pilot orifice following the instructions below. Replace with the propane pilot orifice
Lift the pilot hood
a
off the pilot
assembly.
5
Remove the regulator from the front of the gas control valve. Replace with the propane regulator,
using the new gasket and screws included with the regulator. NOTE: Leak test this area after
the heater is installed, gas is connected, and the main burner is lit.
Remove and discard the three screws using a
slotted screwdriver of Torx T-20.
Slotted
Screwdriver
(or T-20 Torx)
Travis Industries
c
Use a hex wrench to
b
unscrew the orifice.
5/32" Hex
NOTE: when re-attaching,
this pin lines up with the
notch in the pilot hood.
To access the gas
a
control valve, pull on the
piezo igniter to open the
access panel and
expose the gas control
valve.
b
c
Remove and discard the
regulator, diaphram, spring
and center post.
4041220
(Qualified Installers Only)
Remove the orifice and replace with the LP orifice. Screw the
orifice all the way in and replace the pilot hood.
d
Install the LP regulator. Use the screws
included with the LP regulator. Tighten to
approximately 25 Lbs. torque.
NOTE: Make sure the
regulator gasket is correctly
aligned before installation.
Slotted
Screwdriver
(or T-20 Torx)
e
Place the LP label on top of
the control cover near the gas
control valve.
33
Orifice Identification:
LP (Propane) Orifice
35
35
NG (Natural Gas) Orifice
62
9 3 5 0 8 1 2 3