Attachment Method - Sharp AL-2051 Service Manual

Digital multifunctional system
Hide thumbs Also See for AL-2051:
Table of Contents

Advertisement

C. Attachment method
Turn the main switch to the "OFF" position and remove the power
plug from the outlet.
1) Detach the RSPF.
Detach the RSPF from the copier and softly place it on top of
the original table as shown below.
2) Remove the rear cabinet.
<1> Unscrew the screw and remove the rear cabinet
shielding plate. (Save the screw.)
<2> Unscrew three screws and remove the rear cabinet.
(Save the screws.)
<3> Disconnect the connector of the SPF, and remove the
RSPF from the machine.
1
2
3) Remove the rear cover for the document glass.
<1> Remove the two screws and then remove the right glass
holder.
<2> Slide the rear cover for the document glass to remove it.
<3> Remove the table glass.
1
2
3
AL-2051 UNPACKING AND INSTALLATION 5 - 11
4) Attach the Scanner condensation prevention mylar at the 3
positions on the rear side of the main unit as described below.
Note: The hole should be covered with the mylar.
Align the edge of the mylar to the R part (the yellow line in the
diagram below) so that the hole of the metal plate is covered as
much as possible.
Align the edge of the mylar to the R part (the yellow line in the
diagram below) so that the hole of the metal plate is covered as
much as possible.
Attach along the edge of the projection (the yellow line in the
diagram below).

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents