[8] DISASSEMBLY AND ASSEMBLY

Before disassembly, be sure to disconnect the power cord
for safety.
1. Do not disconnect or connect the connector and the
harness while the machine is powered. Especially be
careful not to disconnect or connect the harness between
the MCU PWB and the LSU (MCU PWB: CN5) during the
machine is powered. (If it is disconnected or connected
during the machine is powered, the IC inside the LSU will
be destroyed.)
2. To disconnect the harness after turning on the power, be
sure to turn off the power and wait for at least 10 sec
before disconnection. (Note that a voltage still remains
immediately after turning off the power.)
The disassembly and assembly procedures are described for the
following sections:

1. High voltage section

2. Operation panel section
3. Optical section
4. Fusing section
5. Tray paper feed/transport section
6. Manual paper feed section
7. Rear frame section
8
Power section
9. Duplex motor section
10. Reverse roller section
11. RSPF section
1. High voltage section
A. List
No.
Part name Ref.
1
Transfer charger unit
2
Charger wire
B. Disassembly procedure
1) Press the side cover open/close button and open the side
cover.
1)
2) Push up the lock pawls (2 positions) of the side cover, and
C. Assembly procedure
For assembly, reverse the disassembly procedure.
D. Charger wire cleaning
1) Remove the charger cleaner from the manual paper feed unit.
2)
AL-2051
DISASSEMBLY AND ASSEMBLY 8 - 1
remove the transfer charger.
Transfer
1)
charger
Lock pawl front
1)
Lock pawl rear
1)
2)