Tower, Desktop, LCD Arm, Primate, and Long Range Mounts. Remote, 2000 Hz and Fiber Optic Camera Upgrades.
Brand:
SR Research
| Category:
Accessories
| Size: 4.39 MB
Table of Contents
Table of Contents
3
1 Introduction
9
Suggested Equipment Layout
10
Figure 1-1: Suggested Eyelink 1000 System Layout
10
2 Installation and System Cabling
12
Unpacking
12
Display PC Hardware Installation
12
Setting up the Host PC
13
Rebuilding the Host PC
13
Host PC Wiring
14
Figure 2-1: the Standard Camera (Left) and Fiber Optic Camera Base Box and Camera Head (Right)
14
Standard Camera System Installation
15
Figure 2-2: Host and Display PC Basic Cabling
16
Fiber Optic Camera System Installation
18
Figure 2-3: Fiber Optic Camera Components
18
Figure 2-4: Camera Base Box and Cabling Affixed to the Side of the Host PC
20
The Fiber Optic Camera Adapter
20
Eyelink Response Device Installation
21
Figure 2-5: the Camera Adapter (Left) with Camera Head Inserted (Right)
21
Figure 2-6: Vpixx Button Boxes (Left), Vpixx Button Box Parallel Port Pin Adapter, Modified Gravis Destroyer Gamepad, and Microsoft USB Sidewinder Gamepad (Right)
21
Analog Card Installation
22
Camera Lens Selection
23
3 Tower Mount Installation
24
Figure 3-1: Components of Eyelink 1000 Tower
24
Mounting the Tower to a Table
25
Mounting the High-Speed Camera and Cabling
26
Figure 3-3: Adjust Height of Tower to Half the Screen Area of Monitor
26
Figure 3-4: Views of the Eyelink 1000 Tower and Camera
26
Cabling for the Fiber Optic Camera
27
Cabling for the Standard Camera
27
Figure 3-5: Camera and Illuminator Cables for a Standard Camera Used in the Tower Mount
27
Adjusting Head Rest Components
28
Figure 3-6: Fiber Optic Camera in the Tower Mount
28
4 Desktop Mount / Eyelink Remote Installation
29
Mounting the Eyelink 1000 High-Speed Camera and Cabling
29
Figure 4-1: Eyelink 1000 Desktop Mount Components
29
Figure 4-2: Desktop Mount Camera Adjustment
29
Cabling for the Fiber Optic Camera
31
Cabling for the Standard Camera
31
Figure 4-4: Camera Angled Position for Stabilized Binocular and Monocular Recording
31
Figure 4-5: Camera and Illuminator Cables from Desktop Mount
31
Adjusting the Desktop Mount (Monocular, Binocular and Remote Recording)
32
Figure 4-6: Fiber Optic Camera in the Desktop Mount Viewed from the Front (Left) and Rear (Right)
32
Eyelink Remote Hardware Adjustment for the Desktop Mount
33
5 LCD Arm Mount Installation
34
Choosing a Table
34
Figure 5-1: Typical Eyelink 1000 LCD Arm Mount Installation
34
Figure 5-2: Eyelink 1000 LCD Arm Mount Components: LCD Arm Mount Base, Arm, Camera and LCD Assembly
35
Affixing the Arm Base to a Tabletop
36
Figure 5-3: Two Configurations of the LCD Arm Mount Base
36
Assembling the LCD Arm Components
37
Mounting the Eyelink 1000 High-Speed Camera
38
Attaching the Cables
39
Figure 5-4: Rearview of the LCD Arm Mount's Camera (Top) and LCD Monitor (Bottom)
39
Figure 5-5: Cables Emerging from the Bottom of the LCD Arm
40
Adjusting the Tension Points on the LCD Arm
41
LCD Arm Mount Adjustments for Monocular and Remote Recording
41
Disassembling and Transporting the LCD Arm Mount
42
Figure 5-6: Securing the LCD Arm for Disassembling and Transporting
42
Option 1: Remove LCD Arm and Camera Assembly as a Unit
43
Option 2: Remove Camera Assembly then Remove the LCD Arm
43
6 Primate Mount Installation
44
Figure 6-1: Typical Eyelink 1000 Primate Mount Installation
44
Primate Mount Hardware Considerations
45
7 Long Range Mount Installation
48
Description of the Components
48
Figure 7-1: Eyelink 1000 Long Range Mount Affixed to a Desktop Base (Left) and Pictured with a Variety of Lenses and Tripod Adapter (Right)
48
Overview of Setting the Mount
49
Securing the Eyelink 1000 Fiber Optic Camera Head
50
Figure 7-3: Fiber Optic Camera Head with Lens (Left), Attached to the Camera Head Bracket (Center), Guide Holes in the Camera Head Bracket Accept Guide Pins from Camera Head Clip (Right)
50
Securing the Illuminator
51
Figure 7-4: Bracket in the Level Position (Left) and Angled (Right) - Without the Camera Head (Top) and with the Camera Head (Bottom)
51
Figure 7-5: Illuminator Attached Using Two Brass Thumbscrews (Left), or Single Thumbscrew (Center), Rotates Around the Mounting Bar When Its Knob Is Released to Adjust Tilt (Right)
51
Affixing the Mounting Bar
52
Cabling for Long Range System
52
Figure 7-6: Tripod Adapter (Left), Desktop Base (Middle) and Mounting Bar Attached to the Tripod Adapter Using Two Brass Bolts (Right)
52
Figure 7-7: Male DB-9 Connector (Left-To-Right), Gender Changer with Female Connector Showing, BNC Connectors, LEMO Connectors, and Battery System
53
Long Range Camera Setup
54
Acquire Preliminary Measurements
54
Assemble the Long Range Mount Components
54
Figure 7-8: Focusing the Illuminator
55
Align the Camera Head and Illuminator
56
Put the Mount into Position and Find the Eye
57
Figure 7-9: Pointing the Camera - a Visible Illumination Boundary Indicating Poor Lighting of the Left Portion of the Camera's View (Left) and a Fully Illuminated Target Indicating Intense and Uniform Illumination (Right)
57
Installation in a MEG Room
58
MRI Installation
60
Figure 7-10: Screen Mount Used in Conjunction with the Elekta Neuromag Screen (Left) and a Custom-Built Wood-Frame Screen (Right)
60
Determine the Mount and Configuration to Use
61
Figure 7-11: Tray Mount with Optional Screen for Siemens Family of Scanners (Left), Screen Mount (Middle), and Siemens Allegra Short Bore Mount (Right)
61
Figure 7-12: Tray Mount for Siemens Family of Scanners Pictured from above with
63
User-Supplied Screen (Bottom-Middle), Riser Block on Screen (Top-Right) and from above (Bottom-Right)
63
Mounting the Camera Head and Illuminator
65
The Head Coil Mirror
67
Align the Camera Head and Illuminator
68
Measuring and Using the Eye-To-Camera Distance
68
Put a Volunteer/Confederate in the Scanner and Find the Eye(S)
68
Adjust Image Thresholds and Focus the Lens
69
Calibration and Drift Correcting with the Long Range System
70
Calibrating Atypical Spatial Areas
70
Drift Correction
71
8 Testing the Host PC Installation
73
Running the Eyelink Host Program
73
Figure 8-1: Booting into the Eyelink Partition
73
Figure 8-2: Host Application Camera Setup Screen
74
Figure 8-3: Host PC Set Options Screen
74
Troubleshooting Instructions
75
SCD File Does Not Exist
75
No Hardware" Error
75
Eyelink CL Camera Not Found
75
ERROR: no Sync Found
75
Error: no Optilink Head Found
76
Eyelink Data Storage
76
Customizing Your PHYSICAL.INI Settings
76
Measuring Screen_Phys_Coords
77
Figure 8-4: Measuring Screen_Phys_Cords
77
Measuring Screen_Distance
78
Entering Values into PHYSICAL.INI
78
9 Display PC Software Installation
80
Windows Installation
80
Installing the Eyelink 1000 Experiment Programming Kit
80
Installing the IO Port Access Driver
80
USB License Key Installation
81
Setting up Eyelink 1000 Network Connection
81
System and Programming Tools Required
82
Mac OSX Installation
83
10 Appendix A: Host PC Hardware Installation
84
Installing the High-Speed Frame Grabber - PCI Card
84
Installing the Ethernet Card
84
Figure 10-1: High-Speed Frame Grabber
84
Installing the Data Translation Analog Card (Optional)
85
Figure 10-2: D-Link Ethernet Card
85
Figure 10-3: Analog Card
85
11 Appendix B: Windows 2000/XP Host PC Software Installation
86
Install System Commander
86
Figure 11-1: License Code Entry
86
Resize Existing Disk Partition
87
Figure 11-2: Enable System Commander
87
Figure 11-3: Select Partitioning then Manual Partitioning
87
Figure 11-4: Partition Selection and Resizing
88
Figure 11-5: Partition and Partition Type Selection
88
Create the Eyelink 1000 Host Application Partition
89
Figure 11-6: Create a Custom FAT 32 Partition
89
Copy the Host Application Files to the New Partition
90
Figure 11-7: Windows Explorer Tools Folder Options
90
Configuring the Keyboard
91
Transfer the System to Make the Eyelink Partition Bootable
91
Organize System Commander's 'OS Selection Menu
92
Figure 11-8: Select Partition to Rename
92
Automated Boot into the Eyelink 1000 Operating System
93
Figure 11-9: Select Description and Icons
93
Figure 11-10: Order Add and Remove
93
12 Appendix C: Host PC Software Installation under Windows Vista
94
Formatting the Hard Drive under ROM-DOS
94
Advertisement
Advertisement
Related Products
SR Research EyeLink Portable Duo
SR Research EyeLink II Scene Camera
SR Research EyeLink II
SR Research Categories
Accessories
Digital Camera
Laptop
More SR Research Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL