Sign In
Upload
Manuals
Brands
Gossen MetraWatt Manuals
Test Equipment
SECUTEST BASE10
Gossen MetraWatt SECUTEST BASE10 Manuals
Manuals and User Guides for Gossen MetraWatt SECUTEST BASE10. We have
4
Gossen MetraWatt SECUTEST BASE10 manuals available for free PDF download: Condensed Operating Instructions, Operating Instructions Manual
Gossen MetraWatt SECUTEST BASE10 Condensed Operating Instructions (56 pages)
Test Instruments for Checking the Electrical Safety of Devices
Brand:
Gossen MetraWatt
| Category:
Test Equipment
| Size: 1 MB
Table of Contents
Table of Contents
2
Safety Instructions
3
Applications
5
Intended Use / Use for Intended Purpose
5
Use for Other than Intended Purpose
7
Liability and Guarantee
7
Opening the Instrument / Repairs
7
Documentation
8
Getting Started
8
Test Instrument
9
Scope of Delivery
9
Features
9
Symbols on the Test Instrument
9
Operating and Connection Overview
10
Overview of the Test Instruments' Scope of Functions
11
Characteristic Values
13
Relevant Standards
14
Initial Startup
15
Connecting the Test Instrument to the Mains
15
Automatic Recognition of Mains Connection Errors
15
Connecting Test Probe P1 or P2
16
International Use
16
Operation
17
Basic Test Instrument Operation
17
Entering Text and Numbers
17
User Interface Icons - Parameter and Softkey Icons
18
Test Instrument Settings
19
System Parameters
19
Test Standards
19
Configuration of Integrated Test Sequences
19
Inspector Management
22
Internal Database
22
Creating Test Structures
22
Important Basic Information on Tests and Measurements
23
Important Safety Information
23
Measurement with DUT Connected to Line Voltage
23
Measurement of Insulation Resistance and Equivalent Leakage Current (Alternative Leakage Current Measuring Method)
24
Measuring Parameters for Single
24
Measurements and Test Sequences
24
Single Measurements
25
General
25
Measurement Procedure and Storage
25
RPE - Protective Conductor Resistance for Protection Category I Duts
27
RINS - Insulation Resistance Measurement for Protection Category I Duts
29
RINS - Insulation Resistance Measurement
29
For Protection Category II Duts
29
IPE - Protective Conductor Current
30
Touch Current
31
IE - Device Leakage Current
32
IA - Leakage Current from the Applied Part
33
IP - Patient Leakage Current
34
U - Probe Voltage
35
U - Measuring Voltage
36
Tprcd - Measuring Time to Trip for Prcds
37
P - Functions Test
38
EL1 - Function Test for Extension Cords
39
EXTRA - Special Functions
40
2-Pole Measurement with Test Probes P1 and P2
41
Measurement with Current Clamp Sensor for Permanently Installed PC I Duts
42
Measurements with Test Adapter
43
Test Sequences (Automatic Test Sequences)
44
Measuring Procedure and Storage
45
Example of an Integrated Test Sequence
47
Reports
51
Test Data Management - IZYTRONIQ Software
51
Contact, Support and Service
52
Returns and Environmentally Sound Disposal
53
CE Declaration
54
Advertisement
Gossen MetraWatt SECUTEST BASE10 Condensed Operating Instructions (40 pages)
Testers for Testing the Electrical Safety of Devices per VDE 0701-0702, IEC 62353 and IEC 60974-4
Brand:
Gossen MetraWatt
| Category:
Test Equipment
| Size: 1 MB
Table of Contents
Table of Contents
3
1 Safety Precautions
4
2 Scope of Delivery
6
3 Initial Start-Up
7
Mains Connection
7
Detection of Mains Connection Errors
7
4 Overview of Functions of the Testers
8
5 User Interface Symbols - Parameter and Softkey Symbols
10
6 Internal Database
11
Creation of Test Structures
11
Export - Transmission and Storage of Test
11
Structures and Measurement Data
11
Import (PRO And/Or Feature KB01 Only)
11
7 Data Input
12
Keyboard or Softkey Entries
12
Entry Via Touch Screen (SECUTEST ST PRO And/Or Feature E01 Only)
12
8 Notes on Saving Single Measurements and Test Sequences
13
9 Single Measurements
14
Protection Class I Devices
15
RINS - Insulation Resistance Measurement for Protection Class I Devices
16
RINS - Insulation Resistance Measurement for Protection Class II Devices
17
IPE - Protective Conductor Current
18
IT - Touch Current
19
IE - Device Leakage Current
20
IA - Leakage Current from the Application Part
21
IP - Patient Leakage Current
22
U - Probe Voltage
23
U - Measuring Voltage
24
Tprcd - PRCD Time to Trip
25
(Portable Residual Current Device)
25
P - Functions Test
26
EL1 - Function Testing of Extension Cords
27
EXTRA - Special Functions
28
2-Pole Measurements with P1 and P2 Test
30
Probes
30
Measurement with Current Clamp Sensor at Permanently Installed Duts of Safety Class I
30
Measurements with Test Adapter
31
10 Test Sequences in Accordance with Standards
32
General Procedure
32
Evaluation Procedure
32
Sample Test Sequence
33
11 Measurement Parameters for Individual Measurements and Test Sequences
37
12 Repair and Replacement Parts Service Calibration Center and Rental Instrument Service
38
13 Product Support
38
14 IZYTRONIQ Data Processing Software
39
Gossen MetraWatt SECUTEST BASE10 Operating Instructions Manual (36 pages)
Tester for Measuring the Electrical Safety of Devices per VDE 0701-0702, IEC 62353 and IEC 60974-4
Brand:
Gossen MetraWatt
| Category:
Test Equipment
| Size: 1 MB
Table of Contents
Table of Contents
3
1 Safety Precautions
4
2 Initial Start-Up
6
Mains Connection
6
Detection of Mains Connection Errors
6
3 Overview of Features
7
4 User Interface Symbols - Parameter and Softkey Symbols
8
5 Internal Database
9
Creation of Test Structures
9
Export - Transmission and Storage of Test
9
Structures and Measurement Data
9
Import (PRO And/Or Feature KB01 Only)
9
6 Data Input
9
Keyboard or Softkey Entries
9
Entry Via Touch Keyboard (SECUTEST PRO And/Or Feature E01 Only)
9
7 Notes on Saving Single Measurements and Test Sequences
10
8 Single Measurements
11
RPE - Protective Conductor Resistance for Protection Class I Devices
12
RISO - Insulation Resistance Measurement for Protection Class I Devices
13
Protection Class II Devices
14
IPE - Protective Conductor Current
15
IB - Touch Current
16
IG - Device Leakage Current
17
IA - Leakage Current from the Application Part
18
IP - Patient Leakage Current
19
U - Probe Voltage
20
U - Measuring Voltage
21
Ta - PRCD Time to Trip (Portable Residual Current Device)
22
P - Functions Test
23
EL1 - Testing Extension Cords for Continuity
24
Short-Circuit and Polarity
24
EXTRA - Special Functions
25
2-Pole Measurements with P1 and P2 Test Probes
27
Measurement with Current Clamp Sensor at Permanently
27
Installed Duts of Safety Class I
27
Measurements with Test Adapter
28
9 Test Sequences in Accordance with Standards
29
General Procedure
29
Evaluation Procedure
29
Sample Test Sequence
30
10 Measurement Parameters for Individual Measurements and Test Sequences
33
11 Repair and Replacement Parts Service Calibration Center and Rental Instrument Service
34
12 Product Support
34
13 Report Software
35
Advertisement
Gossen MetraWatt SECUTEST BASE10 Operating Instructions Manual (8 pages)
Firmware Update Tool, Software Program for Updating the Firmware for the Test Instruments
Brand:
Gossen MetraWatt
| Category:
Test Equipment
| Size: 0 MB
Table of Contents
1 Information on the Application
2
Hardware
2
Operating System - Software
2
Supported Devices
2
2 System Requirements
2
Table of Contents
2
3 Installation and Program Sequence
3
Installing the Firmware Update Tool on Your PC
3
Starting the Firmware Update Tool
5
Testing the Files on Your PC and in the Test Instrument
5
Starting the Firmware Update
7
4 Product Support
8
Advertisement
Related Products
Gossen MetraWatt SECULIFE ST BASE 25
Gossen MetraWatt SECULIFE ST BASE(25)
Gossen MetraWatt B100B
Gossen MetraWatt SECUTEST BASE
Gossen MetraWatt SECUTEST PRO BT comfort
Gossen MetraWatt SECUTEST ST BASE
Gossen MetraWatt SECUTEST ST PRO
Gossen MetraWatt SECUTEST ST PRO BT comfort
Gossen MetraWatt SECUTESTSTBASE10
Gossen MetraWatt SECUTEST SIII
Gossen MetraWatt Categories
Measuring Instruments
Test Equipment
Multimeter
Adapter
Power Supply
More Gossen MetraWatt Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL