Fluke Calibration 9500B/600 Calibrator Manuals
Manuals and User Guides for Fluke Calibration 9500B/600 Calibrator. We have
1
Fluke Calibration 9500B/600 Calibrator manual available for free PDF download: Calibration Manual
Fluke Calibration 9500B/600 Calibration Manual (150 pages)
High Performance Oscilloscope Calibrator
Brand:
Fluke Calibration
| Category:
Test Equipment
| Size: 2.16 MB
Table of Contents
Table of Contents
3
Introduction
7
Contact Fluke Calibration Calibration
7
Safety Information
8
Product Use
8
Specifications
8
Routine Maintenance
8
General Cleaning
8
Air Intake Filter
8
Removing the Top Cover
9
Top Guard Shield and Calibration Seal
9
Removing the Filter Element
9
Cleaning the Filter Element
9
Refitting the Filter Element
10
Refitting the Top Cover
10
Replacement Parts
10
Firmware Upgrade
10
Introduction
10
Procedure
11
Active Heads
13
Model 9500B Test and Selftest
13
Types of Tests
13
Test Mode
13
Base, Heads, All and Fast Selftest
14
Aborting the Selftest
15
Selftest Runs to Completion
16
Viewing the Test Results
17
Printing the Test Results
18
Selftest at Power-On
18
Interface Test
19
Access to Interface Tests
19
Display Memory Checks
20
Keyboard Checks
21
Display Checks
22
Memory Card Checks
23
Tracker Ball Checks
27
Printer Checks
28
Printing Selftest Results
29
Introduction
29
Parallel Port (Rear Panel)
29
Printing Setup
30
Printer Type
30
Data Formatting
31
Results Printout
31
Error Reporting Subsystem
31
Error Detection
31
Error Messages
32
System Trip Errors
32
Recoverable Errors
32
Type of Errors
32
Error Reporting
32
Command Errors (CME)
33
Execution Errors (EXE)
34
Query Errors (QYE)
34
Device-Dependent Errors (DDE)
35
Device-Dependent Errors Reported Only Locally on the Front Panel Screen
35
Device-Dependent Errors Reported Only Remotely Via the IEEE-488 Interface
36
Device-Dependent Errors Reported both Locally and Remotely
37
Verification
42
Need for Verification
42
Factory Calibration and Traceability
42
Verification on Receipt from the Factory
42
Verification after User-Calibration
42
Equipment Requirements
42
Interconnections
43
Verification Points
43
Specification Limits
43
Verification Procedure
43
9500B Mainframe Verification by Functions
43
Verifying the DC/Square Function: DC Voltage
44
Verifying the DC/Square Function: Square Voltage
48
Verifying the LF Sine Voltage Function
51
Verifying the Time Markers Function
54
Verifying the Load Resistance Measurement Function
56
Verifying the Pulse Width Function
59
9510/9530/9550/9560 Head Verification by Functions
60
Verifying the Leveled Sine Function: LF Gain
61
Verifying the Leveled Sine Function: Flatness
64
Verifying the Edge Function
71
Verifying the Load Capacitance Measurement Function (Ε)
76
Calibration
80
9500B Mainframe Calibration and Active Head™ Calibration
80
Mainframe Unit Calibration
80
Active Head Calibration
81
Other Functions
81
Mainframe Unit Manual Calibration
82
The Model 9500B Calibration Mode
82
Mode Selection
83
Mode' Key
83
Mode Selection' Screen
84
Selection of Calibration Mode
84
Calibration Enable Switch
84
Password
85
Calibration Mode Display
85
Calibration Mode Screen Softkeys
86
Special Calibration
86
Selecting Special Calibration
86
When to Characterize
87
How to Characterize
87
Form of Characterization
87
Special Cal: 'Adjust FREQ
88
When to Adjust
88
Equipment Requirements
88
Interconnections
89
9500B and Counter Setup
89
Sequence of Operations
89
Mainframe Standard Calibration (BASE CAL)
90
Function Selection
90
Cal Mode Function Screens
91
Hardware Configurations
92
Target Calibration Values
92
Overview of Calibration Operations
92
Standard Calibration - Basic Sequences
94
Aim of Calibration
95
General Calibration Process
95
Target Selection Screen - Selecting Hardware Configurations
95
Waveform Selection
96
Hardware Configurations
96
Channel Selections
96
Retained Channel Memory
97
Default' or 'Saved' Targets
97
The Adjustment Screen
97
Setting Target Values
97
Selecting Default Calibration Targets
98
Modifying a Calibration Target
98
Calibrating the Model 9500B at Target Values
99
Adjust Output Amplitude
99
Target Selection
100
Reset Cal Point
101
Standard Calibration of AC Functions
101
Output Frequency Synthesis
101
Changing the Output Frequency of Target Calibration Points
101
Exit from Base Calibration - Cal Date and Cal Due Date
102
Exit: Mode Key - Warning Screen
103
Exit Only
103
Update the Date Stamp on a Certificate
103
Setting the Cal Due Date and Advance Warning Period
104
Front Panel Base Calibration by Functions
105
Introduction
105
Summary of Calibration Process
106
General Procedure
106
Sequencing Calibrations
108
DC/Square - DC Voltage Calibration
109
DC/Square - Square Calibration
113
LF Sine Voltage Calibration
117
Load Resistance Measurement Calibration
121
9510/9530/9550/9560 Head Calibration Procedures
124
Levelled Sine Function: LF Gain
124
Levelled Sine Function: HF Calibration
126
Calibrating the Edge Function
134
Calibrating the Timing Markers (9510 Only)
146
Load Capacitance Function Calibration (9510 and 9530 Only)
147
Ω / 1 MΩ Ratio Calibration
148
Exit from Head Calibration
150
Advertisement
Advertisement
Related Products
Fluke Calibration 9500B
Fluke Calibration 9500B/1100
Fluke Calibration 9500B/3200
Fluke Calibration 9500B/2200+9560
Fluke Calibration 9190A
Fluke Calibration 4184297
Fluke Calibration 4184411
Fluke Calibration 4184639
Fluke Calibration 4322-SYS-NAVAIR
Fluke Calibration 5080A