Muratec MFX-C4000 Field Engineering Manual page 178

Hide thumbs Also See for MFX-C4000:
Table of Contents

Advertisement

Message
LSU error: #04-004.
Please turn off then on
LSU error: #04-006.
Please turn off then on
LSU error: #04-007.
Please turn off then on
LSU error: #04-009.
Please turn off then on
LSU error: #04-010.
Please turn off then on
Memory failure: #10-001.
Please turn off then on
Motor does not operate:
#03-000. Please turn off
then on
Motor does not operate:
#03-006. Please turn off
then on
Motor does not operate:
#03-007. Please turn off
then on
Motor does not operate:
#03-008. Please turn off
then on
Service Manual
Alignment & Troubleshooting
Meaning
After Yellow LD on, the Laser beam
detect signal is not occurred or
irregular.
Magenta LSU motor does not
operate.
After Magenta LD on, the Laser
beam detect signal is not occurred
or irregular.
Cyan LSU motor does not operate.
After Cyan LD on, the Laser beam
detect signal is not occurred or
irregular.
At system booting, the memory is
not read.
After ITB BLDC motor is operated,
the ready signal is not occurred
within 1 sec.
After Black OPC BLDC motor is
operated, the ready signal is not
occurred within 1 sec.
After Color OPC BLDC motor is
operated, the ready signal is not
occurred within 1 sec.
After Color Dev BLDC motor is
operated, the ready signal is not
occurred within 1 sec.
Suggested Solutions
1. Check the Beam Detecht signal. If there is
a BD signal, replace the Main board. If or
not, check the LD contol signal.
2. Check the LD Power is normal.
3. If it is normal, check the light receving part.
Check the LSU motor noise. If there is any
dirving noise, check the motor signal.
1. Check the Beam Detecht signal. If there is
a BD signal, replace the Main board. If or
not, check the LD contol signal.
2. Check the LD Power is normal.
3. If it is normal, check the light receving part.
Check the LSU motor noise. If there is any
dirving noise, check the motor signal.
1. Check the Beam Detecht signal. If there is
a BD signal, replace the Main board. If or
not, check the LD contol signal.
2. Check the LD Power is normal.
3. If it is normal, check the light receving part.
Replace the memory.
Check the ITB waste toner is eliminated
properly. If the ITB waste toner overflows,
the motor error will be occurred because of
increasing the torque. Replace the developing
unit.
Check the ITB waste toner is eliminated
properly. If the ITB waste toner overflows,
the motor error will be occurred because of
increasing the torque. Replace the developing
unit.
Check the ITB waste toner is eliminated
properly. If the ITB waste toner overflows,
the motor error will be occurred because of
increasing the torque. Replace the developing
unit.
Take out and Shake the developing unit
horizontally. And reinstall it. If the problem
persists, Replace the developing unit.