Code
Displayed Name
109-0002
Fuser Fan Run Ready
109-0003
Fuser Motor Forward
109-0004
Fuser Fan Run
109-0005
Fuser Bias
109-0006
Heater Over Heat Sensor
109-0007
Heater Low Heat Sensor
109-0008
Heater Open Heat Sensor
110-0000
LSU Motor1 Run Ready
110-0001
LSU Motor2 Run Ready
110-0002
LSU Fan1 Run Ready
110-0003
LSU Fan2 Run Ready
110-0004
LSU Clean Motor
110-0005
LSU Clean Sensor
110-0006
LSU Motor1 Run
110-0007
LSU Motor2 Run
110-0008
LSU LD Power1
110-0009
LSU LD Power2
110-0010
LSU LD Power3
110-0011
LSU LD Power4
110-0012
LSU Fan1 Run
110-0013
LSU Fan2 Run
111-0000
Toner Dispense Motor
Yellow
111-0001
Toner Dispense Motor
Magenta
111-0002
Toner Dispense Motor Cyan
Toner Dispense Motor Black Toner Dispense(Supply) Motor On/Off
111-0003
111-0004
Toner Sensor Yellow
111-0005
Toner Sensor Magenta
111-0006
Toner Sensor Cyan
111-0007
Toner Sensor Black
ACR Execute Now
112-0000
113-0000
Finisher Present Sensor
113-0001
Entrance Motor
113-0002
Exit Motor
113-0003
Paddle Motor
Service Manual
Alignment & Troubleshooting
Detects if Fuser Fan Motor runs at normal speed.
Fuser Motor Forward On/Off
Fuser Fan Motor On/Off
Fuser bias voltage on at normal drive level
Detect if the Heater is in Overheat Status.
Detect if the Heater is in Lowheat Status.
Detect if the Heater is in Openheat Status.
Detects if LSU motor1 runs at normal speed.
Detects if LSU motor2 runs at normal speed.
Detects if LSU Fan Motor runs at normal speed.
Detects if LSU Sub Fan Motor runs at normal speed.
Detect if the LSU Clean Motor On/Off
Detect if the LSU Clean Motor is On or Off
LSU Motor1 On/Off
LSU Motor2 On/Off
LSU LD1 Power On/Off (yellow)
LSU LD2 Power On/Off (magenta)
LSU LD3 Power On/Off (cyan)
LSU LD4 Power On/Off (black)
Start/Stop LSU Fan Run
Start/Stop LSU Sub Fan Run
Toner Dispense(Supply) Motor On/Off
Toner Dispense(Supply) Motor On/Off
Toner Dispense(Supply) Motor On/Off
TC sensor in developer tank.
TC sensor in developer tank.
TC sensor in developer tank.
TC sensor in developer tank.
Start Auto Color Registration
Detect if the Finisher is in place.
Entrance Motor run as IOT Speed <about 5 sec>
Exit Motor run as IOT Speed <about 5 sec>
Paddling
4-57
Meaning
State
Displayed
High[Low]
On[Off]
On[Off]
On[Off]
High[Low]
High[Low]
High[Low]
High[Low]
High[Low]
High[Low]
High[Low]
High[Low]
High[Low]
On[Off]
On[Off]
On[Off]
On[Off]
On[Off]
On[Off]
On[Off]
On[Off]
On[Off]
On[Off]
On[Off]
On[Off]
x.xx voltage
x.xx voltage
x.xx voltage
x.xx voltage
Install
[Not Install]
On[Off]
On[Off]
On