Typical Applications - Master Appliance 1425-3550 FPM130-900F Instruction Manual

Master appliance corp. heat gun instruction manual,1425-3550 fpm130-900f
Table of Contents

Advertisement

Available languages

Available languages

Operating Instructions
The proper amount of heat for
each application is dependent
on three variables:
1. The volume/speed of
airflow along with distance
of nozzle from work
surface.
2. Length of time that heat
is applied and airflow.
3. Combination of air and
settings. Experiment with
these variables to better
learn the capabilities of
this heat gun.
Before performing any
application, we recommend
that you experiment with a
piece of scrap material. Use
care in approaching the work
until you
find the proper
combination of heat and air
velocity control, distance and
the heat application time.

Typical Applications

Shrink Packaging
Use low or high heat
Shrink
Tubing
Use low or high heat
Use a gentle back and forth
motion when applying heat
unless it is found that a
concentrated heat is desired.
To Operate Heat Gun
1)
Plug heat gun into properly
rated outlet.
2) Move the switch to position
one (I) for about 130°F54°C
air output, air velocity can
now be regulated between
1425-3550 FPM/434-
1069m/mn.
3) Move the switch to position
two (II) for temperature
control from 130-900°F/54-
482°C. Air velocity is still
controlable from about
1425-3550 FPM/434-
1069m/mn. Air temperature
will stabilize in about two
minutes.
Strip Paint
Use low or high heat
Bend PVC
Tubing
Use high heat
5
4)
Move switch to zero(O)"Off"
position.
CAUTION: Do not place unit
on its side while using
spreader or heat shrink
attachments.
NOTE:
Users should independently
evaluate the suitability of the
product for their application.
Install
Vinyl
Use low or high heat
Dry Film
Use low heat

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proheat variair ph-1300

Table of Contents