SECTION 5 - SPECIFICATIONS

General Specifications
Maximum voltage applied to any terminal : 1000 Vac rms or 1000 Vdc.
rms
Display : 6000 counts.
Polarity Indication : Automatic, positive implied, negative indicated.
Overrange Indication : OL
Batteries Life : 150hours alkaline battery (No backlight)
Low Batteries Indication : Voltage drops below operating voltage, " "
will flash.
Power Requirement : PP3 9V battery
Auto Power Off : 20 minutes.
Operating Temperature :
-10 ~10°C
10°C ~ 30°C (≦80% RH),
30°C ~ 40°C (≦75% RH),
40°C ~ 50°C (≦45%RH)
Storage Temperature : -20°C to 60°C , 0 to 80% R.H. (batteries not
fitted)
Temperature Coefficient : 0.15 x (Spec.Accy) / °C, < 18°C or > 28°C .
Measure : Samples 3 times per second .
Altitude : 6561.7 ft (2000m)
Safety : Complies with EN61010-1, UL61010-1,IEC 61010-1, CAT IV
600V, CAT III 1000V
16
IDM 98III / 99III English
IDM 98III / 99III English
Measurement
Application
Category
Measurements on circuits not directly connected
to mains. Examples include: Measurements on battery
I
powered equipment and specially protected (internal)
mains-derived circuits.
Measurements on circuits directly connected to the
II
low voltage installation. Examples include: Household
appliances, portable tools and similar equipment.
Measurements performed in the building installation.
Examples include measurements on distribution
III
boards, junction boxes, socket-outlets and wiring and
cables in the fixed installation.
Measurements performed at the source of the low-
voltage installation. Examples include measurements
IV
on primary overcurrent protection devices and
electricity Instruments
Weight : 460g (including battery)
Dimensions (W x H x D) : 94mm x190mm x 48mm with holster.
Pollution degree : 2
EMC : EN 61326-1
Shock vibration : Sinusoidal vibration per MIL-PRF- 28800F
(5 ~ 55 Hz, 3g max.)
Drop Protection : 4 feet drop to hardwood on concrete floor.
Indoor use only.