Terminal Position - Ferroli Econcept 50 A Installation And Operating Instructions Manual

Wall-hung, pre-mix gas- fired condensing boiler
Table of Contents

Advertisement

Terminal Position

Minimum dimensions of flue terminal positions
Dimensions
A a
B a
C a
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
NOTE N/A = Not applicable
a
I
n addition, the terminal should not be nearer than 150 mm (fanned draucht) or 300 mm (natural draught) to an opening in the building fabric
formed for the purpose of accommodating a built-in element such as a window frame, (see Figure C2). Separation distances are linked to the
rated heat inputs as shown.
18
Supplied By www.heating spares.co Tel. 0161 620 6677
B
J
G
Terminal position
(kW input expressed in net)
Directly below an opening, air brick, (0-7 kW)
opening windows, etc.
(>14-32 kW)
(>32-70 kW)
Above an opening, air brick, (0-7 kW)
opening windows, etc.
(>14-32 kW)
(>32-70 kW)
Horizontally to an opening, air brick, (0-7 kW)
opening windows, etc.
(>14-32 kW)
(>32-70 kW)
Below gutters, soil pipes or drain pipes
Below eaves
Below balconies or car port roof
From a vertical drain pipe or soil pipe
From an internal or external corner
Above ground roof or balcony level
From a surface facing the terminal
(also see 6.1.2)
From a terminal facing the terminal
From an opening in the car port ( e.g. door,
window) into the dwelling
Vertically from a terminal on the same wall
Horizontally from a terminal on the same wall
From the wall on which the terminal is mounted
From a vertical structure on the roof
Above intersection with roof
P
D, E
C
A
Fig. 12
(>7-14 kW)
(>7-14 kW)
(>7-14 kW)
Econcept 50 A
N
N
Balanced flues room
sealed
Fanned
draught
300 mm
300 mm
300 mm
75 mm
200 mm
200 mm
150 mm b
300 mm
300 mm
600 mm
1200 mm
1200 mm
1500 mm
300 mm
N/A
N/A
N/A