Terminal Position - Ferroli MODENA 80 E Installation, Servicing And User Instructions Manual

Copper wall-mounted combination, gas fired boiler for central heating and domestic hot water production, fan assisted, room sealed compartment, electronic flame ignition and control
Table of Contents

Advertisement

CLEARANCES:
* 600mm minimum clearance for servicing
access

Terminal Position

POSITION
MINIMUM SPACING
A
Directly below an openable window, air vent, or any other ventilation opening
B
Below gutters, soil pipes or drainpipes
C
Below Eaves
D
Below a Balcony
E
From vertical drainpipes or soilpipes
F
From internal or external corners
G
Above adjacent ground or balcony level
H
From a surface facing the terminal
I
Facing another terminal
J
From opening (door/window) in carport into dwelling
K
Vertically from a terminal on the same wall
L
Horizontally from a terminal on the same wall
N
Below carport
A Quinnel Barrat and Quinnel guard (part. No. C2) should be screwed to the wall centrally over the terminal, when
the terminal height is less than 2 m from floor level.
MODENA 80 E
Fig. 11
Fig. 12
5 min.
460
5 min.
270
50 mm
600* min.
mm
300
75
100
100
75
100
100
600
1,200
1,200
300
300
600