Test OUT
The function is used to test exit settings and to
calculate the distance from the charging station to a
remote area.
To test the settings in Remote start 1:
Dock the robotic lawnmower in the charging station
and select Test OUT . The mower will then leave the
charging station straight away along the guide wire
and begin mowing after the designated distance.
If there is a passage that the mower cannot get
through, the settings in Guide width (2-1) ought to be
changed from Wide to Medium. If required, the
setting can also be changed to Narrow. The Narrow
guide width setting should only be used if none of the
other settings work for this installation. When the
Test OUT function is activated, the mower travels the
farthest distance from the wire allowed by the
selected guide width.
The figure here shows how the robotic lawnmower
travels through a passage when Guide width is set to
Medium and not to Wide.
How to measure the distance from the charging
station to a remote area:
Enter a distance which beyond any doubt exceeds
the real figure. The maximum distance that can be
entered is 100 metres. Dock the robotic lawnmower in
the charging station and select Test OUT . The robotic
lawnmower will immediately leave the charging station.
The distance, stated in metres, will be shown in the
mower display as the mower operates. Stop the
robotic lawnmower at the required position and note
the distance. Enter the displayed number of metres in
the Distance field for the working area in question.
If Remote start 2 has been activated, i.e. if another
option other than Never has been selected for
Proportion, these settings must also be tested.
Remote start 2 test is performed in the same way as
for Remote start 1.
Test IN
The Test IN function allows you to test how well the
robotic lawnmower docks with the charging station.
Test IN can only be performed after Test OUT has
been performed.
Selecting this function causes the mower to travel
directly along the guide wire towards the charging
station and docks with it. The test is approved only if
the mower is able to dock with the charging station at
the first attempt. If the mower is unable to dock on the
first attempt, it will automatically try again. The
installation is not approved if the mower needs two or
more attempts to dock with the charging station.