Improvements have been done in the calibration of guide. The purpose of calibration of guide is that the guide width setting should have the same width (50 cm and 100 cm), irrespective of garden layout. SERVICE 90˚ 90˚ B1100028 English 1 (5) 305 before delivery to ® 3020-017...
Page 2
- Always remove the blades from the blade disc whenever Automower demonstrated in public areas for increased safety. - Demonstration of Automower the mower is constantly under observation. SERVICE without using demo mode may only be done if ® B1100028 English 2 (5) ® ®...
Replace MMI circuit board problem Keyboard problem Check that wire between keyboard and MMI circuit board is properly connected. Replace keyboard Replace MMI circuit board Display problem Replace MMI circuit board Parameter problem Replace MMI circuit board SERVICE B1100028 English 3 (5)
5. Confirm that Autocheck EXP establish connection with the mower. At the bottom of the Autocheck EXP window the model name (305) and serial number should be visible. SERVICE 305 and connect it to Autocheck EXP via a USB cable (part ® B1100028 English 4 (5) 305. ®...
Page 5
SERVICE B1100028 English 5 (5) 6. Choose Programming -> Program in the top menu. 7. Under the heading Automatic programming, click Start. 8. Update of Main software and MMI software has been completed when the text Programming finished appears under the heading Status.