Barco RLM W8 Service Manual page 65

Hide thumbs Also See for RLM W8:
Table of Contents

Advertisement

Note9:
pip.sel can NOT be set to 0.
Note10: Not applicable
when pip is off.
Note11: Not applicable
when lamp is cooling.
Note12: Not applicable when eco.net.pow is on.
Note13: Only MCU version number will be read back in standby mode.
Note14: Not applicable when the internal pattern is displayed.
Note15: The summation of the absolute value of h.keystone and v.keystone should not be greater than 350.
Note16: Per Geo Semi's specification, the minimum blend size is 200, values in the range 1 ~ 99 are not
allowed if no 4-corner adjustment, values in the range 1~ 199 are not allowed if there is 4-corner
adjustment.
Note17: Per Geo Semi's specification, black level (position) adjustment will only work with an active
white level setting on the corresponding side.
Note18: When scen.red, scen.green, scen.blue values are not equal, the command will get back "NA"in
reading.